SWIMMING POOL HEAT PUMP User and service manual
POMPE À CHALEUR POUR PISCINE Manuel d’installation et d’utilisation
ZWEMBAD WARMTEPOMP Gebruiker en service manual
BOMBA DE CALOR PARA PISCINA Manual del usuario y de servicio
SCHWIMMBAD - WÄRMEPUMPE Benutzer - und Wartungshandbuch
PISCINA POMPA DI CALORE Istruzioni per l'uso e di servizio
BOMBA DE CALOR DE PISCINA Manual do usuário e serviço
PRO ELYO INVERBOOST NN
EN
FR
NL
IT
ES
DE
PT

Questions and Answers

  • M
    Michelle MedinaSep 12, 2025
    What to do if my Astralpool Heat Pump has a gas return sensor failure?
    • R
      Rebecca RossSep 13, 2025
      If your Astralpool Heat Pump shows a gas return sensor failure, it could be due to the sensor being in an open or short circuit, or the wiring of the sensor being loose. Check or change the sensor and re-fix the wiring of the sensors.
  • M
    Matthew MasonAug 25, 2025
    What to do if my Astralpool PROELYXP14i Heat Pump shows a water flow failure TS1?
    • M
      Mr. Justin Moreno MDAug 25, 2025
      If your Astralpool Heat Pump displays a water flow failure TS1, it could be due to a damaged water flow switch or insufficient water flow. Try replacing the water flow switch or checking the filtration pump and waterway system to ensure adequate water flow.
  • K
    Kayla ButlerAug 25, 2025
    Why is my Astralpool PROELYXP14i Heat Pump showing compressor current protection?
    • M
      Michelle MichaelAug 26, 2025
      Compressor current protection in your Astralpool Heat Pump can occur due to several reasons: the compressor current being too large instantaneously, incorrect connection for compressor phase sequence, compressor accumulations of liquid and oil, a damaged compressor or driver board, abnormal water flow, or power fluctuations. To resolve this, check the compressor, compressor phase, power range, phase sequence connection, the waterway system and filtration pump, and mains power input.
  • C
    Cindy WilsonSep 23, 2025
    What to do if my Astralpool Heat Pump has The inter-chip communication failure on the main control board?
    • K
      Kevin KingSep 23, 2025
      If your Astralpool Heat Pump experiences an inter-chip communication failure on the main control board, it indicates a main board failure. Turn off the electricity supply and restart it, or change the main board.
  • J
    jasmine77Sep 13, 2025
    What to do if my Astralpool Heat Pump has an ambient temperature sensor failure T5?
    • A
      Amber RobinsonSep 13, 2025
      If your Astralpool Heat Pump shows an ambient temperature sensor failure T5, it could be due to the sensor being in an open or short circuit, or the wiring of the sensor being loose. Check or change the sensor and re-fix the wiring of the sensors.
  • S
    Samantha MartinezSep 23, 2025
    What does compressor phase failure mean for my Astralpool Heat Pump?
    • M
      Marc DunnSep 23, 2025
      Compressor phase failure in your Astralpool Heat Pump means that the compressors U, V, W are connected to one phase or two phases. Check the actual wiring according to the circuit diagram.
  • Q
    qsmithSep 6, 2025
    What to do if my Astralpool PROELYXP14i shows IPM module temperature too high protection?
    • L
      Laura PerrySep 6, 2025
      If your Astralpool Heat Pump displays an IPM module temperature too high protection error, it could be due to an output exception of the IPM module thermal circuit, an abnormal or damaged motor, or a broken fan blade. Try changing the driver board, checking if the fan motor speed is too low or fan motor is damaged, or changing the fan blade.
  • R
    ralvarezSep 7, 2025
    What causes PFC module protection in Astralpool PROELYXP14i?
    • A
      Ann DuranSep 7, 2025
      PFC module protection in your Astralpool Heat Pump can be triggered by an output exception of the PFC module, an abnormal or damaged motor, a broken fan blade, or abnormal input power. To solve this, change the driver board, check if the motor speed is too low or fan motor is damaged, change the fan blade, or check the input voltage.
  • M
    Mrs. Kendra DiazSep 23, 2025
    What to do if my Astralpool PROELYXP14i Heat Pump has four-way valve reversal failure?
    • A
      Alexandra McguireSep 23, 2025
      If your Astralpool Heat Pump experiences a four-way valve reversal failure, it may be due to the valve failing to reverse or a lack of refrigerant. Switch to cooling mode to check if the 4-way valve has been reversed correctly, change the 4-way valve, or fill with gas.
  • M
    melindahuntAug 31, 2025
    How to resolve communication failure between Main control board and Driving board in Astralpool Heat Pump?
    • D
      Daniel Gomez PhDAug 31, 2025
      A communication failure between the Main control board and Driving board in your Astralpool Heat Pump is likely caused by a poor connection of the communication wire or a damaged wire. Check the wire connection and replace the wire if necessary.

Summary

Specifications

Location and Connection

5.1 Heat Pump Location

Details optimal placement requirements and considerations for the heat pump unit.

5.4 Initial Operation

Outlines the procedure for starting the heat pump for the first time.

Electrical Wiring

Wiring Diagrams

Visual schematics showing electrical connections for various heat pump models.

6.6 Electrical Connection

Provides guidelines and specifications for connecting the heat pump to the power supply.

Start-up of the Heat Pump

7.2.12 Auto Mode

Describes the unit's auto mode, including heating, cooling, and switching logic.

7.3 Heating Operation Logic

Details the operational logic and parameters for heating modes.

7.4 Cooling Operation Logic

Details the operational logic and parameters for cooling modes.

Troubleshooting

8.1 Error Code Display on LED Wire Controller

Lists error codes, their causes, and recommended solutions.

8.2 Other Malfunctions and Solutions (No display on LED wire controller)

Addresses issues not indicated by error codes and their resolutions.

Exploded Diagram

Astralpool PROELYXP14i Specifications

General IconGeneral
ModelPROELYXP14i
Heating Capacity14 kW
Power Supply230V / 1ph / 50Hz
Power Consumption2.8 kW
COP5.0
RefrigerantR32
Noise Level52 dB(A)
Compressor TypeRotary
Heat ExchangerTitanium
Max Water Temperature40°C
Water Flow Rate4.0 m³/h
Operating Temperature Range-10°C to +43°C