SWIMMING POOL HEAT PUMP User and service manual
POMPE À CHALEUR POUR PISCINE Manuel d’installation et d’utilisation
ZWEMBAD WARMTEPOMP Gebruiker en service manual
BOMBA DE CALOR PARA PISCINA Manual del usuario y de servicio
SCHWIMMBAD - WÄRMEPUMPE Benutzer - und Wartungshandbuch
PISCINA POMPA DI CALORE Istruzioni per l'uso e di servizio
BOMBA DE CALOR DE PISCINA Manual do usuário e serviço
PRO ELYO INVERBOOST NN
EN
FR
NL
IT
ES
DE
PT

Questions and Answers

  • B
    benjaminkeySep 1, 2025
    What does 'low ambient temperature protection' mean for my Astralpool PROELYXP14i Heat Pump?
    • N
      Natalie GarciaSep 1, 2025
      The 'low ambient temperature protection' message on your Astralpool Heat Pump indicates that the unit is either being used outside of its intended environment or that there is a sensor abnormality. Stop using the unit if it is beyond its operating scope, or change the sensor.
  • J
    jillian09Sep 2, 2025
    What causes piping temperature too high protection under cooling mode T3 in Astralpool Heat Pump?
    • T
      teresacarterSep 2, 2025
      Piping temperature too high protection under cooling mode T3 in your Astralpool Heat Pump can be caused by a high ambient or water temperature, or an abnormal refrigeration system. Check the scope of using and the refrigeration system.
  • R
    rachel37Sep 3, 2025
    What to do if my Astralpool Heat Pump displays IPM module protection?
    • T
      Thomas WestSep 3, 2025
      If your Astralpool Heat Pump displays an IPM module protection error, it could be due to a data mistake, wrong compressor phase connection, compressor liquid and oil accumulation, or a damaged compressor or driver board. You can try turning off the electricity supply and restarting after 3 minutes, changing the driver board, or checking the compressor sequence connection.
  • T
    Timothy MunozSep 4, 2025
    What does 'VDC voltage too low protection' mean for my Astralpool Heat Pump?
    • T
      Theresa AllenSep 4, 2025
      The 'VDC voltage too low protection' error in your Astralpool Heat Pump indicates that the line voltage is too low or the driver board is damaged. Check if the power is in the normal range or change the driver board.
  • J
    julia45Sep 4, 2025
    What causes input current over high protection in my Astralpool Heat Pump?
    • A
      Antonio PerkinsSep 5, 2025
      Input current over high protection in your Astralpool Heat Pump can be caused by a large momentary compressor current, abnormal water flow, power fluctuations, or an incorrect PFC inductor. Try checking the compressor, the waterway system, the power range, and if the correct PFC inductor is used.
  • S
    Shawn MartinezSep 5, 2025
    How to troubleshoot IPM module thermal circuit abnormality in Astralpool PROELYXP14i Heat Pump?
    • M
      Michelle Carson DDSSep 5, 2025
      An abnormal IPM module thermal circuit in your Astralpool Heat Pump can be caused by an output abnormality of the IPM module thermal circuit or a problem with the fan motor (abnormal or damaged) or a broken fan blade. Try changing the driver board, checking if the motor speed is too low or fan motor is damaged, or changing the fan blade.
  • Q
    qsmithSep 6, 2025
    What to do if my Astralpool PROELYXP14i shows IPM module temperature too high protection?
    • L
      Laura PerrySep 6, 2025
      If your Astralpool Heat Pump displays an IPM module temperature too high protection error, it could be due to an output exception of the IPM module thermal circuit, an abnormal or damaged motor, or a broken fan blade. Try changing the driver board, checking if the fan motor speed is too low or fan motor is damaged, or changing the fan blade.

Summary

Specifications

Location and Connection

5.1 Heat Pump Location

Details optimal placement requirements and considerations for the heat pump unit.

5.4 Initial Operation

Outlines the procedure for starting the heat pump for the first time.

Electrical Wiring

Wiring Diagrams

Visual schematics showing electrical connections for various heat pump models.

6.6 Electrical Connection

Provides guidelines and specifications for connecting the heat pump to the power supply.

Start-up of the Heat Pump

7.2.12 Auto Mode

Describes the unit's auto mode, including heating, cooling, and switching logic.

7.3 Heating Operation Logic

Details the operational logic and parameters for heating modes.

7.4 Cooling Operation Logic

Details the operational logic and parameters for cooling modes.

Troubleshooting

8.1 Error Code Display on LED Wire Controller

Lists error codes, their causes, and recommended solutions.

8.2 Other Malfunctions and Solutions (No display on LED wire controller)

Addresses issues not indicated by error codes and their resolutions.

Exploded Diagram

Astralpool PROELYXP14i Specifications

General IconGeneral
ModelPROELYXP14i
Heating Capacity14 kW
Power Supply230V / 1ph / 50Hz
Power Consumption2.8 kW
COP5.0
RefrigerantR32
Noise Level52 dB(A)
Compressor TypeRotary
Heat ExchangerTitanium
Max Water Temperature40°C
Water Flow Rate4.0 m³/h
Operating Temperature Range-10°C to +43°C

Related product manuals