INST 272 SALT EXPERT Salt Chlorinator (V06-17) Page 13
5.2 Troubleshooting (T Model)
Your SALT EXPERT Chlorinator has diagnostic and safety features to make it easy to
maintain your system. The table below summarises potential faults and their causes.
Fault Indication
Remedy
No Flow
Ensure valves/pump on
Connect Blue sense wire to
cell
Low salt
See section 3.5 above
See section 3.5 above
See section 4.1
Call a technician
Display blank
Plug in controller and
ensure mains power
available
Replace fuse (3 amp slow
blow)
Low/No chlorine
production
Connect cables
Increase timer period
Increase chlorine output
Backwash filter
Get pH level correct
Get Stabiliser between 30
and 60 ppm
Increase salt to above
4000ppm
Clock loses time
when mains
power removed
Call a technician