Fault Indication Possible Cause Remedy
No Flow Pump turned off/disconnected or valves closed
Sense wire disconnected from cell
Ensure valves/pump on
Connect sense wire to cell
Low salt Salt level in pool has dropped too low
Pool water temperature is low
Cell has failed
Increase salt level or raise water temperature
Call a technician
Sense wire disconnected from
cell
For models with a temp sensor this error can be caused
by low conductivity.
Lack of salt < 4000 ppm due to water loss or dilution
(filter backwash, water renewal, rain, leaks, etc.).
Can vary depending on the temperature and age of
the cell. The voltage across the cell terminals varies in
time.
Cell calcified, worn, or out of order.
Check water temperature.
Check the condition of the cell plates.
Measure the salt concentration in the pool water using
a salt tester or a test strip, then add salt to the pool to
keep the level at 4000 ppm. If you do not know the salt
level or how to test it, contact your retailer.
Is the salt level is correct?
Check Light Mode A Light Timer is set, but the light is set to ON or OFF
instead of AUTO
Use the “LIGHT” button or RF remote control to set the
Light to AUTO mode
Check Timer The Pump is set to OFF in all timers Modify timers so that the Pump is on in at least 1 timer.
Display blank No Power to Controller
Fuse blown
Plug in controller and ensure mains power available
Call a technician
Low/No chlorine production Cables not connected to cell
Timer period too short
Chlorine output level too low
Filter needs backwashing
Pool stabiliser too low
Salt level too low
Water Temperature below 15 deg
Excessive Salt Level (Above 10,000 ppm)
The e-Q has locked out on fail safe with very low
chlorine levels present (less than 100 mv ORP)
Connect cables
Increase timer period
Increase chlorine output
Backwash filter
Get Stabiliser between 30 and 60 ppm
Increase salt to 4000ppm
Increase water temperature or salt level
Chlorinator cuts out on overload, reduce salt level to
4000 ppm
Test Chlorine levels and add chlorine to pool. Start pool
pump and allow one hour for sensor to read chlorine
levels
Pool water cloudy Chemical balance in incorrect
Acid container empty
ORP level set too low
Pool water volume set too low in install menu
Insufficient Water flow
Insufficient water turnovers each day
Test Water and adjust as needed pH 7.2 to 7.6, TA to 120
ppm and CH to 180ppm
Replace Acid Container
Set ORP to 700 mv
Increase pool water volume
Increase variable speed of pump
Increase water turns in Install menu
pH too high Probe/sensor malfunction
Clean and calibrate probe/sensor
Chlorine too high ORP level is set too high
Total Alkalinity too low
ORP sensor is not immersed in pool water
Cyanuric Acid (Chlorine Stabiliser) is present in pool
Reduce to between 600 and 650 mv ORP
Test TA and adjust to 80 to 120 ppm
Install sensor chamber so that it is always in pool water
Lower ORP set point
Table 5. Troubleshooting