Page #16 background image
Page GB-16
Heatingcircuit
Push for approx. 3
seconds
Programming of operating times
6622..55
1155::3300
WWEE.. 2255 .. JJUUNN..;;0033
°C
TTIIMMEEPPRROOGGRRAAMMSS
HHCC
TTIIMMEEPPRROOGGRRAAMMSS
MMCC--11
TTIIMMEEPPRROOGGRRAAMMSS
TTIIMMEEPPRROOGGRRAAMMSS
MMCC--22
Enter timeprogram level
Standard display
DDHHWW
TTIIMMEEPPRROOGGRRAAMMSS
select
accept
Example: Unmixed circ.
accept
With this mode of operation individual timeprograms can be generated for heating and hot-water
mode. For this purpose the factory preset standard program (P1) is called up after selecting the res-
pective circuit and can be individually overwritten.
For the programming of timeprograms, a maximum of three heatingcycles with a switch-on and
switch-off time each is available for each weekday. Apart from that a desired room temperature or
domestic hot water temperature can be assigned to each heating or domestic hot water cycle.
3sec
if necessary select program, if enabled (see page 25)
1) 1)
GB
8A521100_GB.qxd 10.11.2004 12:05 Seite 16