EasyManua.ls Logo

Atag VA4611AT - Manual Adjustment; Electronic Adjustment

Atag VA4611AT
60 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Water hardness
Water softener
adjustment
German
degrees
(°dH)
French
degrees
(°fH)
mmol/l Clarke
degrees
Manual Elec-
tronic
23 - 28 40 - 50 4.0 - 5.0 28 - 35
2
1)
6
19 - 22 33 - 39 3.3 - 3.9 23 - 27
2
1)
5
1)
15 - 18 26 - 32 2.6 - 3.2 18 - 22 1 4
11 - 14 19 - 25 1.9 - 2.5 13 - 17 1 3
4 - 10 7 - 18 0.7 - 1.8 5 - 12 1 2
< 4 < 7 < 0.7 < 5
1
2)
1
2)
1) Factory position.
2) Do not use salt at this level.
You must adjust the water softener
manually and electronically.
Manual adjustment
Turn the water hardness dial to the position
1 or 2.
Electronic adjustment
1. Press the on/off button to activate the
appliance. Make sure that the appliance
is in setting mode, refer to ‘SETTING
AND STARTING A PROGRAMME’.
2. Press and hold buttons (4) and (5) at the
same time until the indicators of buttons
(3), (4) and (5) flash.
3. Press button (3).
The indicators of buttons (4) and (5)
go off.
The indicator of button (3) continues
to flash.
The acoustic signals operate, e.g. five
intermittent acoustic signals = level 5.
The display shows the setting of the
water softener, e.g.
= level 5.
4. Press button (3) again and again to
change the setting.
5. Deactivate the appliance to confirm the
setting.