Atag VA9011ZT - Test Program Details; Sequence Test Program VA(9)6211 TT

Atag VA9011ZT
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product information
VA3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
-
23 -
Error codes
A Aqua sensor calibrating error red sensor
B Aqua sensor calibrating error green sensor
C No tacho pulse
D Circulation pump short circuit
E No pulse from water hardness sensor
F Filling error
G Triac water hardness sensor short circuit
H Heating error
I - - -
J - - -
K NTC error, interrupted / short circuit
L Opto sensor, error or no communication ( does not apply)
M Relay power supply stuck
N Net synchronisation not possible
O Safety level activated
P Safety level (O) 8 x recognized
Sequence test program VA(9)6211TT
0 Pumping 30
1 Opto sensor PTC switched on 2
2 Filling soft water - Aqua sensor - Opto sensor 1 litre
3 Pause - Aqua sensor (red) 2
4 Filling hard water - Aqua sensor (red) 1 litre
5 Pause - Aqua sensor (red) 2
6 Filling hard water - Aqua sensor (red) tot F1
7 Pause 2
8 Aqua sensor (green) 60
9 Outlet valve heat exchanger 60
10 Regeneration valve 10
11 Control soap dispenser 90
12 - 17 water renewal positioning BK / OK
18 Circulation pump (relay sub coil sicasym)10 + 20 OK
19 Water renewal positioning BK
20 Circulating 20 BK
21 Circulating + heating 250 max. 67 °C Rinsing
22 Pumping 5
23 Circulating 5