Error codes
A Aqua sensor calibrating error red sensor
B Aqua sensor calibrating error green sensor
C No tacho pulse
D Circulation pump short circuit
E No pulse from water hardness sensor
F Filling error
G Triac water hardness sensor short circuit
H Heating error
I - - -
J - - -
K NTC error, interrupted / short circuit
L Opto sensor, error or no communication ( does not apply)
M Relay power supply stuck
N Net synchronisation not possible
O Safety level activated
P Safety level (O) 8 x recognized
Sequence test program VA(9)6211TT
0 Pumping 30
1 Opto sensor PTC switched on 2
2 Filling soft water - Aqua sensor - Opto sensor 1 litre
3 Pause - Aqua sensor (red) 2
4 Filling hard water - Aqua sensor (red) 1 litre
5 Pause - Aqua sensor (red) 2
6 Filling hard water - Aqua sensor (red) tot F1
7 Pause 2
8 Aqua sensor (green) 60
9 Outlet valve heat exchanger 60
10 Regeneration valve 10
11 Control soap dispenser 90
12 - 17 water renewal positioning BK / OK
18 Circulation pump (relay sub coil sicasym)10 + 20 OK
19 Water renewal positioning BK
20 Circulating 20 BK
21 Circulating + heating 250 max. 67 °C Rinsing
22 Pumping 5
23 Circulating 5