Load recognition
Tacho recognizes shortage of
water because of irregular running.
After levelling the machine runs
quietly again
Motor RPM is measured by means of a tacho generator.
Speed control is applied by means of electronic phase shifting.
• Load recognition.
• RPM reduction during soft programs
• RPM reduction at rinsing change (shifting from upper basket washing to
lower basket washing)
• Different RPM for upper basket washing relative to lower basket washing
(2200 / 2800 1/min)