Operation and maintenance manual AQUAmax
®
BASIC/CLASSIC
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 28 from 40
Fault Possible cause Rectification
There is no indication on the
control display.
• The plant is without power. • Check pre-fusing and/or
residual current circuit
breaker.
• The display is defective. • Call Service.
Acoustic alarm sounds. There
is no indication on the control
display.
• The plant is without power.
UVS
®
has triggered.
• Check pre-fusing and/or
residual current circuit
breaker.
• The display is defective. • Call Service.
“Fault” with the description of
the electrical unit involved
appears on the display.
• The unit or the complete
AQUAmax
®
is not
connected with the control
system.
• Connect the appropriate
unit.
• A screw terminal in the
cable distribution box or on
the terminal strip of the
control unit is not correctly
tightened, so that the
connection is interrupted.
• Have the contact points and
the cabling checked by an
electrician.
• The connection cable from
the electrical unit to the
control box is interrupted.
• Defect rectification see
above.
• The fine fuse of the
corresponding unit has
triggered.
• Change fuse.
• The water level in the
aeration stage is so low
that the pump runs dry.
• Defect rectification see
above.
• The corresponding unit is
blocked or runs rough
(check power
consumption).
• Remove AQUAmax
®
clear
blockages.
• The corresponding
electrical unit is defective.
• Call Service.