Operation and maintenance manual AQUAmax
®
BASIC/CLASSIC
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 28 from 40
Fault Possible cause Rectification
There is no indication on the
control display.
The plant is without power. Check pre-fusing and/or
residual current circuit
breaker.
The display is defective. Call Service.
Acoustic alarm sounds. There
is no indication on the control
display.
The plant is without power.
UVS
®
has triggered.
Check pre-fusing and/or
residual current circuit
breaker.
The display is defective. Call Service.
“Fault” with the description of
the electrical unit involved
appears on the display.
The unit or the complete
AQUAmax
®
is not
connected with the control
system.
Connect the appropriate
unit.
A screw terminal in the
cable distribution box or on
the terminal strip of the
control unit is not correctly
tightened, so that the
connection is interrupted.
Have the contact points and
the cabling checked by an
electrician.
The connection cable from
the electrical unit to the
control box is interrupted.
Defect rectification see
above.
The fine fuse of the
corresponding unit has
triggered.
Change fuse.
The water level in the
aeration stage is so low
that the pump runs dry.
Defect rectification see
above.
The corresponding unit is
blocked or runs rough
(check power
consumption).
Remove AQUAmax
®
clear
blockages.
The corresponding
electrical unit is defective.
Call Service.