Operation and maintenance manual AQUAmax
®
BASIC/CLASSIC
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 29 from 40
Fault Possible cause Rectification
The treatment performance of
the plant is unsatisfactory.
Most of the above given defects
can lead to a reduction in
treatment performance.
In addition, there can be many
reasons given for unsatisfactory
discharge values, such as:
insufficient oxygen supply
Faulty position of the
submersible aerator
leaking of the tank
discharge of large
quantities of detergents or
disinfectants as well as
other non-permitted
substances
(paints, solvents, etc.)
sludge disposal not carried
out
faulty settings of the
population figures
plant disconnected from the
power supply for longer
period
In the interests of the
environment you should get in
contact with your service
operation in order to achieve an
improvement in the discharge
values.
Important data for the fault diagnosis of the electrical units (All units 230 V AC)
Submersible aerator R
Ha
[] I
Load
[A] P [kW]
AQUA 3 32 1.3 0.27
AQUA 5 14 2.5 0.56
AQUA 200 SV 27 1.1 0.35
Submersible motor pumps
ATBlift 1 32 1.1 0.25
ATBlift 2 32 1.25 0.30
NOVA 180 SV 46 0.9 0.24
NOVA 200 SV 27 1.5 0.35
FEKA 600 8 4.3 1.0