33
In case of a device with shared power and control voltage supply (Î Fig. 12)
no automatic restarting of the drive takes place after a power failure or the
tripping of the protective device.
Caution!
In case of a device with a separate control voltage supply
(ÎFig. 13) an automatic restart of the drive takes place after
a failure in the power supply.
After a power failure in the control voltage supply there is no
automatic restart of the drive.
A failure in the control voltage triggers the reset of the PTC
tripping device.
Warning!
The compact drive feeds voltage also when the device is off.
Before performing work on the device or external control unit,
disconnect the mains line.