5. Refrigeration connection
Precautions: :
The refrigeration lines must be thermally insulated
scalding and ensure optimal performance.

performance and service life of the system. The tubes must be free from bends.
The 2 tubes that make up the refrigeration line must be separately insulated.

The installation must be correctly vacuum sealed to ensure correct operation and
guarantee the reliability of the system over time.






Plugged
Pressure resistance: minimum 50 bar
Minimum tube thickness 0.8 mm
Maximum tube thickness 1.0 mm
This type of refrigeration lines are available as accessories.
5.1. Shaping

to prevent any risk of crushing or breakage.

Do not bend the copper to an angle of more than 90°.
Do not bend the line more than three times at the same point (risk of incipient break
age and strain hardening of the metal).
Release the lines from their insulation so that you can properly bend them using the

using adhesive tape.