Operation
4812160001_A.pdf2014-08-25
Amplitude - Changeover
1
Fig. Control panel
1. High amplitude
The amplitude setting must not be change when
vibration is in operation
Switch the vibration off and wait until vibration
stops before changing amplitude.
The amplitude setting must not be change when
vibration is in operation
Switch the vibration off and wait until vibration
stops before changing amplitude.
By pressing button (1) high amplitude is achieved.
Braking
Normal braking
2
3
1
Fig. Control panel
1. Vibration On/Off switch
2. Forward/Reverse lever
3. Parking brake
Press the switch (1) to switch off the vibration.
Move the forward/reverse lever (2) to the neutral
position to stop the roller.
Always activate the parking brake (3), before leaving
the operator platform.
When starting and driving a machine that is cold,
remember that the hydraulic fluid is also cold and
that braking distances can be longer than normal
until the machine reaches the working temperature.
When starting and driving a machine that is cold,
remember that the hydraulic fluid is also cold and
that braking distances can be longer than normal
until the machine reaches the working temperature.
If the forward/reverse lever is moved quickly (forwards
or backwards) toward/past neutral, the system
switches to a rapid braking Mode and the machine
stops.
Activate normal driving Mode again by moving the
forward/reverse lever back to neutral.
67