ETP TBP81-55-10 EN Troubleshooting
© Atlas Copco Industrial Technique AB - 9839 0853 01
27
Troubleshooting
Troubleshooting Guide
Problem Reason Action
Tool does not shut off or tightening
time is too long.
Target torque close to maximum
torque of the tool.
Chose a bigger tool with more
power.
Worn extension or socket/bits. Check the extension and socket/
bits.
Incorrect oil level in the Pulse unit. Adjust the oil level or refill the oil.
The joint is too soft for the tool. Choose a bigger tool with more
power or increase pulse energy.
Worn parts in the Pulse unit. Inspect and replace any worn
parts.
The yield point of the joint is
reached.
Check the joint specification.
Inconsistent shut off or insufficient
accuracy.
The target torque is not within the
tool specification.
Change to a different tool size.
Extension is too long. Change to shorter extension.
Worn extension or socket/bits. Replace the extension and socket/
bits.
Incorrect oil level in the Pulse unit. Adjust the oil level or refill the oil.
The joint is too stiff. Choose a smaller tool or decrease
pulse energy.
If the tool becomes very hot. Very high prevailing torque. Change to a different tool size.
Very soft joints. Change to a different tool size.
High cycle rate. Change to a different tool size.
Events and Error Codes
For a full list of tool event and error codes, see Power Focus 6000 Configuration Manual.