Instruction
book
ϭϬ
1904 0504 83
All guards are in place and securely fastened
All hoses and/or pipes inside the machine are in good condition, secure and not rubbing
No leaks occur
All fasteners are tight
All electrical leads are secure and in good order
Safety valves and other pressure relief devices are not obstructed by dirt or paint
Air outlet valve and air net, i.e. pipes, couplings, manifolds, valves, hoses, etc. are in good
repair, free of wear or abuse
Air cooling filters of the electrical cabinet are not clogged
C C D
If warm cooling air from compressors is used in air heating systems, e.g. to warm up a
workroom, take precautions against air pollution and possible contamination of the breathing
air.
C E D
On water-cooled compressors using open circuit cooling towers, protective measures must be
taken to avoid the growth of harmful bacteria such as Legionella pneumophila bacteria.
C F D
Do not remove any of, or tamper with, the sound-damping material.
C G D
Never remove or tamper with the safety devices, guards or insulations fitted on the machine.
Every pressure vessel or auxiliary installed outside the machine to contain air above
atmospheric pressure shall be protected by a pressure relieving device or devices as required.
C
H
D
Yearly inspect air receiver. Minimum wall thickness as specified in the instruction book must be
respected. Local regulations remain applicable if they are more strict.
Also consult following safety precautions:
Safety precautions during
installation
and Safety precautions during maintenance.
These precautions apply to machinery processing or consuming air or inert
gas. Processing of any other gas requires additional safety precautions
typical to the application which are not included herein.
Some precautions are general and cover several machine types and
equipment; hence some statements may not apply to your machine.
All responsibility for any damage or injury resulting from neglecting these
precautions, or non-observance of the normal caution and care required for
installation, operation, maintenance and repair, even if not expressly stated,
will be disclaimed by the manufacturer.
N
? > @
8 A : ; < 9 B O A
?
; 9 P S 8 ; 9 :
>
9 8 9
@ >
<
? ? >
6 8 ;
?
Maintenance and repair work shall only be carried out under supervision of someone qualified for the
job
To maintain warranty and to insure the compressor operates correctly and safety, genuine parts must
be used. Use of non-genuine parts, failure to correctly install equipment or perform recommended
scheduled maintenance will void warranty and result in damage to or failure of the equipment. This
could also result in fire and fatalities.
Always use the correct safety equipment such as safety glasses, gloves, safety shoes, etc.
Before performing any maintenance, stop the compressor, close the shut-off valve at the unit
discharge, remove all electrical power from the equipment, verify the receiver tank on the unit is at zero
pressure and let the machine cool down. Take positive precaution to ensure that the unit cannot be
started inadvertently by following a lock-out tag-out procedure. In addition, a warning sign bearing a
legend such as
^
]
<
? _
; 9 6
?
< P
? >
B B ` O < 9 < : B : 8
?
: a
shall be attached to the starting equipment