Instruction book
1904 0504 83
ϳ
In a domestic environment, this product may cause radio interference in which
case supplementary mitigation measures are required.
If the machine is equipped with an automatic restart after voltage failure function
and if this function is active, be aware that the machine will restart automatically
when the power is restored if it was running when the power was interrupted
C E D
Never play with compressed air. Do not apply the air to your skin or direct an air stream at
people. Never use the air to clean dirt from your clothes. When using the air to clean equipment,
do so with extreme caution and wear eye protection.
C F D
The owner is responsible for maintaining the unit in safe operating condition. Parts and
accessories shall be replaced if unsuitable for safe operation.
C G D
It is not allowed to walk or stand on the roof of the compressor canopy.
All responsibility for any damage or injury resulting from neglecting these
precautions, or non observance of the normal caution and care required for
installation, operation, maintenance and repair, even if not expressly stated,
will be disclaimed by the manufacturer
.
N
? > @
8 A : ; < 9 B O A
?
; 9 P < 6
> ?
8 : ; < 9
C D
Apart from general engineering practice in conformity with the local safety regulations, the
following directives are specially stressed:
E D
In proposals/quotes to the customer it should be mentioned mandatory to ask for lockable
isolators at customer installation, the same has to be added in AIB for commissioning/servicing
of the machine. Need of lockable isolators to be clearly communicated to customers.
F D
A compressor shall be lifted only with adequate equipment in conformity with local safety rules.
Please consult Atlas Copco to check if a dedicated lifting devise is designed for this purpose.
Loose or pivoting parts shall be securely fastened before lifting. It is strictly forbidden to dwell or
stay in the risk zone under a lifted load. Lifting acceleration and retardation shall be kept within
safe limits.
G D
The units is designed for indoor use . If the unit is installed outdoors, special precautions must
be taken; consult your supplier.
H
D
In case the devise is a compressor, place the machine where the ambient air is as cool and
clean as possible if necessary, install a suction duct. Never obstruct the air inlet. Care must b
taken to minimize the entry of moisture at the inlet air
I D
Any blanking flanges, plugs, caps and desiccant bags must be removed before connecting the
pipes.
J
D
Air hoses must be of correct size and suitable for the working pressure. Never use frayed,
damaged or worn hoses. Distribution pipes and connections must be of the correct size and
suitable for the working pressure.
K D
In case the devise is a compressor, the aspirated air must be free of flammable fumes, vapours
and particles, e.g. paint solvents, that can lead to internal fire or explosion.
L D
In case the dives is a compressor, arrange the air intake so that loose clothing worn by people
cannot be drawn in.
C M D
Ensure that the discharge pipe from the compressor to the aftercooler or air net is free to
expand under heat and that it is not in contact with or close to flammable materials.
C C D
No external force may be exerted on the air outlet valve; the connected pipe must be free of
strain.
C E D
If remote control is installed, the machine must bear a clear sign stating: DANGER: This
machine is remotely controlled and may start without warning.
The operator has to make sure that the machine is stopped and depressurized and that the