Instruction
book
ϮϮ
1904 0504 83
[
?
8 ; 9
@
< 9 9
> @
: ; < 9 B
The compressors have an centrifugal water separator WSD25 (1). The condensate formed in the air
cooler accumulates in the collector. When the condensate reaches a certain level, it is discharged
through the automatic drain outlet (Da). Also, the condensate water can be discharged manually through
the manual drain outlet (Dm).
On Full-Feature compressors, an additional centrifugal water drain WSD25 (2) is provided. The
condensate trap of the heat exchanger is drained by WSD25 and discharged through automatic drain
outlet (Da1). Also, the condensate water can be discharged manually through the manual drain outlet
(Dm1).
n o s o p s m r o u p ~ r s ~ s
>
R
> ? >
9
@ >
[
>
B ; P 9 8 : ; < 9
Da Automatic drain connection
Dm Manual drain connection
Da1 Automatic drain connection of the dryer (only on Full-Feature units)
Dm1 Manual drain connection of the dryer (only on Full-Feature units)