2920 1461 03
35
User manual
Dewpoint -70° variant 50Hz
Combination UNLOADING LOADING
GA and ICD
GA Model ICD model Minimum Nominal Maximum Minimum Nominal Maximum
Unloading Unloading Unloading Loading Loading Loading
Pressure Pressure Pressure Pressure Pressure Pressure
bar bar bar bar bar bar
GA30 - 7.5 CD140 6.1 6.5 6.8 6.0 6.0 6.7
GA30 - 7.5 CD170 5.5 6.5 6.8 5.4 6.0 6.7
GA30 - 8 CD140 6.0 7.0 7.3 5.9 6.5 7.2
GA30 - 8 CD170 5.3 7.0 7.3 5.2 6.5 7.2
GA30 - 10 CD100 6.7 9.0 9.3 6.6 8.5 9.2
GA30 - 10 CD140 5.5 9.0 9.3 5.4 8.5 9.2
GA30 - 10 CD170 4.9 9.0 9.3 4.8 8.5 9.2
GA30 - 13 CD100 9.9 12.0 12.3 9.8 11.5 12.2
GA30 - 13 CD140 8.1 12.0 12.3 8.0 11.5 12.2
GA30 - 13 CD170 7.2 12.0 12.3 7.1 11.5 12.2
GA37 - 7.5 CD170 6.1 6.5 6.8 6.0 6.0 6.7
GA37 - 8 CD140 6.8 7.2 7.3 6.7 6.7 7.2
GA37 - 8 CD170 6.0 7.0 7.3 5.9 6.5 7.2
GA37 - 10 CD100 8.6 9.0 9.3 8.5 8.5 9.2
GA37 - 10 CD140 6.3 9.0 9.3 6.2 8.5 9.2
GA37 - 10 CD170 5.6 9.0 9.3 5.5 8.5 9.2
GA37 - 13 CD100 11.0 12.0 12.3 10.9 11.5 12.2
GA37 - 13 CD140 9.1 12.0 12.3 9.0 11.5 12.2
GA37 - 13 CD170 8.1 12.0 12.3 8.0 11.5 12.2
GA45 - 8 CD170 6.4 7.0 7.3 6.3 6.5 7.2
GA45 - 10 CD140 7.4 9.0 9.3 7.3 8.5 9.2
GA45 - 10 CD170 6.4 9.0 9.3 6.3 8.5 9.2
GA45 - 13 CD140 10.4 12.0 12.3 10.3 11.5 12.2
GA45 - 13 CD170 9.3 12.0 12.3 9.2 11.5 12.2
GA55C - 10 CD170 7.1 9.0 9.3 7.0 8.5 9.2
GA55C - 13 CD140 11.6 12.0 12.3 11.5 11.5 12.2
GA55C - 13 CD170 10.4 12.0 12.3 10.3 11.5 12.2
GA55 - 7.5 CD280 5.9 6.5 6.8 5.8 6.0 6.7
GA55 - 8 CD230 6.4 7.0 7.3 6.3 6.5 7.2
GA55 - 8 CD280 5.7 7.0 7.3 5.6 6.5 7.2
GA55 - 10 CD170 7.4 9.0 9.3 7.3 8.5 9.2
GA55 - 10 CD230 6.0 9.0 9.3 5.9 8.5 9.2
GA55 - 10 CD280 5.3 9.0 9.3 5.2 8.5 9.2
GA75 - 8 CD280 6.9 7.3 7.3 6.8 6.8 7.2
GA75 - 10 CD230 7.4 9.0 9.3 7.3 8.5 9.2
GA75 - 10 CD280 6.4 9.0 9.3 6.3 8.5 9.2
GA75 - 13 CD230 10.6 12.0 12.3 10.5 11.5 12.2
GA75 - 13 CD280 9.5 12.0 12.3 9.4 11.5 12.2
GA90C - 10 CD230 8.5 9.0 9.3 8.4 8.5 9.2
GA90C - 10 CD280 6.8 9.0 9.3 6.7 8.5 9.2
GA90C - 13 CD230 11.3 12.0 12.3 11.2 11.5 12.2
GA90C - 13 CD280 10.1 12.0 12.3 10.0 11.5 12.2