Model | GA75 |
---|---|
Category | Air Compressor |
Power | 75 kW |
Capacity FAD | 13.5 m³/min |
Working Pressure | 7.5 bar |
Voltage | 400 V |
Free Air Delivery | 13.5 m³/min |
Motor Power | 75 kW |
Specific directives and precautions for the installation of compressors and air dryers.
Overview of the Elektronikon I regulator's functions and basic operation.
Detailed description of the buttons, LEDs, and display on the control panel.
Explanation of the display elements, pictographs, and main screen.
Information on conditions triggering shut-down warnings for temperature and dewpoint.
Details on compressor shut-down conditions, including temperature and motor overload.
Explanation of service warnings and their indications on the display.
Procedure for navigating through various information screens on the regulator.
Specifies the minimum, nominal, and maximum unloading and loading pressures for various compressor models.
Defines the warning and shut-down temperature settings for the compressor element outlet.
Details the nominal warning setting for dewpoint temperature.
Provides information on the nominal setting for the service timer based on oil type.
Overview of the Elektronikon II regulator's functions, including automatic control and protection.
Description of the control panel components for the Elektronikon II regulator.
Explanation of menu-driven programs for compressor control and programming.
Procedure to quickly view the current status of the compressor.
Information on compressor status, including protection functions and message types.
Procedure to access measured data and input statuses, including motor overload protection.
How to access running hours, loaded hours, motor starts, and other counter data.
Procedure for performing a display test to check pixels and LEDs.
Overview of parameters that can be programmed via the Modify Params menu.
Guide to modifying various operational parameters of the regulator.
Procedure for adjusting shut-down, shut-down warning, and warning settings for compressor protection.
Instructions on how to modify the running hour intervals for service plans.
Details on programming time-based start/stop and pressure band commands for the compressor.
Procedure for reprogramming various parameters, including time and control modes.
Functionality to reset service plans and check upcoming or past service actions.
How to access compressor data saved by the regulator, such as last shut-down data.
Table listing minimum, nominal, and maximum values for various programmable parameters.
Details on protection parameters like element outlet temperature and delays.
Defines the running hours for Service plans A, B, and C.