PAGE
9
Repair Instruction No. 174.3/95
PHE 26 RA
1 Grease the pinion reception (8).
2 Put the thrust piece (9) in the grease.
F
Insert the thrust piece as shown in
illustration.
3 Insert the rear part (8) of the extraction
housing together with the armature into
the motor housing (7) and secure with
screws (5).
4 Fit the gasket (4) and apply some silicon
(10) to the area of the aspiration hole.
5 Fit the front part of the extraction housing
together with the end shield (2) to the
rear part (6) and secure with the screws
(1).
Assembling the
extraction
housing
5
1 2 3 4 675
31 2
transparent
violet
grey
A1
E1
E2
A2
red
blue
black
yellow
21 3
grey
6
1
2
3
45 6
7
1
2
3
4563
1 Insert the carbon brush holders (6).
2 Insert the carbon brushes (5) and hang up
the tension springs (4) with clasp.
3 Insert the AVS-rubber (2) and the guiding
rollers (3).
4 Mount the handle cover (1) on the motor
housing.
5 Insert the electrical parts in the handle
cover and connect them according to the
connection diagram.
F
Make sure the cables fit properly in the
housing. Cables must never be jammed
when assembling.
Assembling the
electrical parts
1 Insert the AVS-rubber (1).
2 Fasten the handle cover (2) with screws.
3 Fasten the mains cable (4).
4 Fasten the strain relief (5).
5 Fasten the service cover (6) with screws.
F
After the high-voltage check, fit the
Softgrips (3).
Assembling the
handle