42 2954 2100 01
QAS 14 - 20 Pd
Climatic exposure open air open air
Degree of protection (cubicle) IP54 IP54
Status of neutral earthed earthed
Alternator 4)
Standard IEC34-1 IEC34-1
ISO 8528-3 ISO 8528-3
Make NEWAGE NEWAGE
Model BCI 164 D1 BCI 164 D1
Rated output, class H temp. rise 13.5 kVA 16.9 kVA
rating type acc. ISO 8528-3
BR BR
Degree of protection IP 23 IP 23
Insulation stator class H H
Insulation rotor class H H
Number of wires 12 12
Engine 4)
Standard ISO 3046 ISO 3046
ISO 8528-2 ISO 8528-2
Type PERKINS 403C-15 403C-15
Rated net output 12 kW 14.4 kW
rating type acc. ISO 3046-7
ICXN ICXN
Coolant water water
Combustion system direct injection direct injection
Aspiration natural aspirated natural aspirated
Number of cylinders 3 3
Swept volume 1.496 l 1.496 l
Speed governing mechanical mechanical
(optional) electronic electronic
Capacity of oil sump 6 l 6 l
capacity of cooling system 3.6 l 3.6 l
Electrical system 12 Vdc 12 Vdc
Power circuit
Circuit-breaker, 3ph
Number of poles 4 4
Thermal release It (Thermal release is higher at 25°C) 20 A 20 A
Magnetic release Im 3..5xIn 3..5xIn
Circuit-breaker, 3ph, lower voltage
Number of poles 3 4
Thermal release It (Thermal release is higher at 25°C) 32 A 40 A
Magnetic release Im 3..5xIn 3..5xIn
Fault current protection
Residual current release IDn 0.030-30 A 0.030-30 A
Insulation resistance (optional) 10-100 kOhm -
Outlet sockets domestic (1x) none
2p + E
16A 230V
CEE form (1x)
3p + N + E
16A + 400V
CEE form (1x)
3p + N + E
32A + 400V
Unit
Dimensions (LxWxH) 2070 x 870 x 1188 mm 2070 x 870 x 1188 mm
Weight net mass 921 kg 921 kg
Weight wet mass 969 kg 969 kg