EasyManuals Logo

Atlas Copco XAHS 950 CD7 T3 APP User Manual

Atlas Copco XAHS 950 CD7 T3 APP
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #91 background imageLoading...
Page #91 background image
- 91 -
COLD WEATHER PACKAGE
The cold start option consists of larger batteries
and a blow off valve to be able to start the engine
at temperatures between -10°C (14°F) and -25°C
(-13°F). It also includes a preheater.
INLET SHUTDOWN VALVE
The inlet shut down valve is a safety device
preventing the engine from over speeding when
sucking in combustible fumes. When the engine max.
RPM is exceeded a pneumatically controlled solenoid
valve closes off the air inlet and the fuel supply to the
engine is cut.
FUELXPERT
This is a control module that regulates engine speed
and the air inlet to optimise fuel consumption
depending on the working conditions, and the output
required.