CLEANING COOLERS
Keep the coolers clean to maintain the cooling
efficiency.
Remove the baffle (1). Then clean by air jet in reverse
direction of normal flow.
Steam cleaning in combination with a cleansing agent
may be applied.
Install the baffle (1).
Remove any dirt from the coolers with a
fibre brush. Never use a wire brush or
metal objects.
(1)
To avoid damaging the coolers, angle
between jet and coolers should be
approx. 90° (do not use jet at max.
power) .
Protect the electrical and controlling
equipment, air filters, etc. against
penetration of moisture.
Never leave spilled liquids such as fuel,
oil, water and cleansing agents in or
around the compressor.