- 38 -
REPLACING THE AIR FILTER ELEMENT
The instructions apply to one air filter and should be
repeated for both air filters engine and air filters
compressor.
1. Release the snap clips (1) and remove the dust trap
(2). Clean the trap.
2. Remove the element (3) and Safety Cartridge (4)
from the housing (5). If the element is to be serviced
for immediate re-use, reinstall the dust trap to protect
the air intake system while cleaning the element.
3. Discard the filter element when damaged.
4. A dirty safety cartridge (3) is an indication of a mal-
functioning filter element.
5. Reassemble in reverse order of dismantling.
6. Inspect and tighten all air intake connections.
7. Reset the vacuum indicator by pushing the reset but-
ton (8).
AIR RECEIVER
The air receiver (1) is tested according to official
standards. Regularly have inspections carried out in
conformity with local regulations.
Safety Valve
Following checks must be carried out:
A check of the opening of the lifting gear, twice a
year. This can be done by lifting the ring or lever.
A check of the set pressure once a year according to
the local regulations. This check cannot be done on
the machine and must be carried out on a proper test
bench.
Fuel System
Replacing the filter element:
1. Unscrew the final filter element (1) from the adapter
head.
2. Clean the adapter head sealing surface. Lightly oil
the gasket of the new element and screw the latter
onto the header until the gasket is properly seated
and then tighten with both hands.
3. After replacing the final filters element, prime fuel
system with manual prime pump.
4. Check for fuel leaks once the engine has been
restarted.
All adjustments or repairs are to be done by
an authorized representative of the valve
supplier.
Drain condensate daily.