Technical Specifications
Reference conditions
The inlet conditions are specified at the air inlet grating outside the canopy.
Limitations
Designation XAS 185 CDU
Absolute inlet pressure bar(e) 1
psi 14.7
Relative air humidity % 0
Air inlet temperature °C 20
°F 68
Normal effective working pressure bar(e) 7
psi 100
Designation XAS 185 CDU
Minimum effective receiver pressure bar(e) 4
psi 58
Maximum effective receiver pressure,
compressor unloaded
bar(e) 8.4-8.7
psi 120-125
Maximum ambient temperature at sea level °C 52.78
°F 127
Minimum starting temperature °C -7.7
°F 18
Minimum starting temperature,
with coldstart equipment
°C -25
°F -13
Altitude capability see curve

Table of Contents