XAS97 Dd
3.1.4 L
IFTING
INSTRUCTIONS
Fig. 3.9 Lifting eye
When lifting the compressor, the hoist has to be placed in such a way
that the compressor, which must be placed level, will be lifted
vertically. Keep lifting acceleration and retardation within safe
limits.
Preferably use the lifting eye (1) after opening the small door (2).
3.2 B
EFORE
STARTING
1. Before initial start-up, prepare battery for operation if not already
done. See section 4.8.
2. With the compressor standing level, check the level of the engine
oil. Add oil, if necessary, to the upper mark on dipstick. Consult
the Engine Operation Manual for the type and viscosity grade of
the engine oil.
3. Check the level of the compressor oil. The pointer of oil level
gauge (Fig. 2.3, OLG) should register in the green range. Add oil
if necessary. See section 4.3 for the oil to be used.
4. Check that the fuel tank contains sufficient fuel. Top up, if
necessary. Consult the Engine Operation Manual for the type of
fuel.
5. Drain any water and sediment from the fuel filter until clean fuel
flows from the drain cock.
6. Press vacuator valves (Fig. 2.3, VV) of the air filter to remove
dust.
7. Check the air filter vacuum indicators (Fig. 2.3, VI). If the yellow
piston reaches the red marked service range, replace the filter
element. Reset the indicator by pushing the reset button.
8. Open air outlet valve to allow air flow to the atmosphere.
Lifting acceleration and retardation must be kept
within safe limits (max. 2g).
Helicopter lifting is not allowed.
1
2
Before removing oil filler plug (Fig. 2.3, FP), ensure that
the pressure is released by opening an air outlet valve.

Table of Contents