EasyManua.ls Logo

Atlas Copco XRHS 1100 CD6 - Specific start procedure

Atlas Copco XRHS 1100 CD6
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instruction Manual
42 2954 2510 03
3.4.4 Specific start procedure
Follow this start procedure when the compressor is put in operation for the first time and after
running out of fuel or changing the fuel filter.
Fuel filter
Loosen the vent screw (1) on the fuel filter.
Operate the hand pump (2) at the filter until fuel comes out of the bore for the vent screw, and
air is completely removed from the fuel system.
Fasten the vent screw (1).
Switch the “ON/OFF” switch to position ”ON”. The instrument panel will now perform a brief
selftest.
Push the start button and the starter motor will automatically try to start the engine.
After cleaning/draining the fuel tanks, the system is filled with air.
Before starting the engine operate the fuelpump on the fuelfilter to fill the
fuelsystem. Loosen the vent screw (1) on the fuel filter. Operate the hand pump
(2) at the filter until fuel comes out of the bore for the vent screw, and air is
completely removed from the fuel system. Fasten the vent screw (1).
When under pressure the engine will start after approximately 10 seconds. If
the system is not under pressure, it will take a few minutes untill the engine will
start.
(1)
(2)

Table of Contents

Related product manuals