5.4 Fuel system
5.4.1 Priming instructions
Prime the fuel system in order to fill the fuel filter. Prime the fuel system in order to purge trapped
air (see paragraph 3.4.4 Specific start procedure). The fuel system should be primed under the
following conditions:
Compressor is put in operation for the first time
Running out of fuel
Storage
Replacement of the fuel filter
Fuel leaked or spilled onto hot surfaces or electrical components can cause a
fire. To help prevent possible injury, turn the “ON/OFF” switch in position
“OFF” when changing fuel filters or water separator elements. Clean up fuel
spills immediately.
Do not loosen the fuel lines at the fuel manifold. The fittings may be damaged
and/or a loss of priming pressure may occur when the fuel lines are loosened.