- 47 -
SOOT LOAD reaches 92%
When still no DPF regeneration is forced the next
warning alarm will pop-up.
Additionally the machine will be prevented to Load:
Required Action:
• Acknowledge the ‘LOAD PREVENTION -
HIGH DPF SOOT LOAD’ inhibit load alarm
(press Enter while in the Main View).
• Force DPF Regeneration, see paragraph FORCE
DPF REGENERATION
When a DPF Regeneration is started, the DPF
Regeneration Needed icon will disappear and the
HEST icon will pop-up.
SOOT LOAD reaches 98%
When no DPF regeneration is forced, the controller
will force the machine into Not Loaded.
Required Action:
• Acknowledge the ‘ECU DPF SOOT LOAD
HIGH’ warning (press Enter while in the Main
View).
• Force DPF Regeneration, see paragraph FORCE
DPF REGENERATION
When DPF Regeneration is started, the DPF
Regeneration Needed icon will disappear and the
HEST icon will pop-up.
SOOT LOAD reaches 101%
If still no action is taken the following warning
appears and the controller will perform a controlled
shutdown.
As soon as the engine is stopped, the DPF
Regeneration Needed icon will disappear (engine
electronics are powered down).
DPF Regeneration needed
MAIN VIEW
LOADED
18.6
7110 LOAD PREVENTION - HIGH DPF SOOT LO...
DPF Regeneration needed
MAIN VIEW
NOT LOADED
18.6
7100 ECU DPF SOOT LOAD HIGH
Contact Atlas Copco for further actions
to be taken.
MAIN VIEW
SHUTDOWN
18.6
7120 SOOT LOAD TOO HIGH - CALL ATLAS CO...