- 50 -
Change Display Settings
Press the SETTINGS VIEW button
scroll to ‘1000 GENERAL SETTINGS’
press ENTER
scroll to ‘1310 DISPLAY BACKLIGHT’
ENTER the DISPLAY BACKLIGHT menu
scroll to the setting you would like to change
press ENTER.
To change a setting, the red figure is editable.
Scroll up/down and press ENTER to change. Use left/
right to shift between editable figure.
Now press BACK until you’re back in the Main View
(or in the menu you require).
Go To Diagnostics
Press the SETTINGS VIEW button
scroll to ‘1000 GENERAL SETTINGS’
press ENTER
scroll to ‘1150 DIAGNOSTICS
ENTER the Diagnostics menu,
ENTER the ‘ENABLE’ parameter
scroll to ‘ON’ and press ENTER.
Now the ECU will get PAC (ignition) and one can
perform ECU diagnostics (read DM1 List, DM2 List,
ECU values, perform engine diagnostics, …).
Now press BACK until you’re back in the Main View
(or in the menu you require).
To leave Diagnostics, press the STOP button.