Use the check box Internet Protocol version +4 (TCP/IPv4) (1) (see picture). To avoid conflicts,
uncheck other properties if they are checked. After selecting TCP/IPv4, click on the Properties button
(2) to change the settings.
Use the following settings:
IP Address 192.168.100.200 (1)
Subnetmask 255.255.255.0 (2)
Click OK (3) and close network connections.
Configure a company network (LAN) connection
Ask your IT department to generate a fixed IP address in your company’s network.
That IP address will be excluded from the DNS server, so it will be reserved for the Elektronikon
Mk5.
Also get the correct Gateway and Subnet mask settings. For example:
IP = 10.25.43.200
Gateway = 10.25.42.250