Minimum
setting
Factory
setting
Maximum
setting
Compressor element 2 outlet temperature
(shut-down level)
˚C 100 220 220
Compressor element 2 outlet temperature
(shut-down level)
˚F 212 428 428
Protection settings
Minimum
setting
Factory
setting
Maximum
setting
Compressor element 1 outlet temperature
(shut-down warning level)
˚C 100 225 234
Compressor element 1 outlet temperature
(shut-down warning level)
˚F 212 437 453
Compressor element 1 outlet temperature
(shut-down level)
˚C 100 235 235
Compressor element 1 outlet temperature
(shut-down level)
˚F 212 455 455
Compressor element 2 outlet temperature
(shut-down warning level)
˚C 100 225 234
Compressor element 2 outlet temperature
(shut-down warning level)
˚F 212 437 453
Compressor element 2 outlet temperature
(shut-down level)
˚C 100 235 235
Compressor element 2 outlet temperature
(shut-down level)
˚F 212 455 455
Protection settings
Minimum
setting
Factory
setting
Maximum
setting
Compressor element 2 inlet temperature
(shut-down warning level)
˚C 40 65 79
Compressor element 2 inlet temperature
(shut-down warning level)
˚F 104 149 174
Compressor element 2 inlet temperature
(shut-down level)
˚C 40 70 80
Compressor element 2 inlet temperature
(shut-down level)
˚F 104 158 176
Oil temperature (shut-down warning level) ˚C 40 65 79
Oil temperature (shut-down warning level) ˚F 104 149 174
Oil temperature (shut-down level) ˚C 40 70 80
Oil temperature (shut-down level) ˚F 104 158 176
Oil pressure (shut-down warning level) bar(e) 1.0 1.3 1.2
Oil pressure (shut-down warning level) psig 14.5 18.9 17.4
Instruction book
72 2920 1815 04