Minimum
setting
Factory
setting
Maximum
setting
Compressor element 2 outlet temperature
(shut-down warning level) (10.0, 10.4 and
12.0 bar compressors)
Compressors designed for a maximum
inlet temperature of 40 ˚C
˚C 100 225 235
Compressors designed for a maximum
inlet temperature of 104 ˚F
˚F 212 437 455
ZR Compressors designed for a maximum
inlet temperature of 50 ˚C
˚C 100 225 235
ZR Compressors designed for a maximum
inlet temperature of 122 ˚F
˚F 212 437 455
ZT Compressors designed for a maximum
inlet temperature of 50 ˚C
˚C 100 255 260
ZT Compressors designed for a maximum
inlet temperature of 122 ˚F
˚F 212 491 500
Compressor element 2 outlet temperature
(shut-down warning level) (13.0 bar
compressors)
Compressors designed for a maximum
inlet temperature of 40 ˚C
˚C 100 225 235
Compressors designed for a maximum
inlet temperature of 104 ˚F
˚F 212 437 455
ZR Compressors designed for a maximum
inlet temperature of 50 ˚C
˚C 100 225 235
ZR Compressors designed for a maximum
inlet temperature of 122 ˚F
˚F 212 437 455
ZT Compressors designed for a maximum
inlet temperature of 50 ˚C
˚C 100 255 260
ZT Compressors designed for a maximum
inlet temperature of 122 ˚F
˚F 212 491 500
Compressor element 2 outlet temperature
(shut-down level) (10.0, 10.4 and 12.0 bar
compressors)
Compressors designed for a maximum
inlet temperature of 40 ˚C
˚C 226 235 235
Compressors designed for a maximum
inlet temperature of 104 ˚F
˚F 439 455 455
ZR Compressors designed for a maximum
inlet temperature of 50 ˚C
˚C 226 235 235
ZR Compressors designed for a maximum
inlet temperature of 122 ˚F
˚F 439 455 455
ZT Compressors designed for a maximum
inlet temperature of 50 ˚C
˚C 256 260 260
ZT Compressors designed for a maximum
inlet temperature of 122 ˚F
˚F 493 500 500
Compressor element 2 outlet temperature
(shut-down level) (13.0 bar compressors)
Instruction book
108 2920 1815 04