Supply voltage
(V)
Recommended overload setting F21
(A)
380 239
440 204
460 197
575 159
ZR/ZT 200 compressors designed for a maximum inlet temperature of 50 ˚C/122 ˚F with IE2 motor
or equipped with oversized IE2 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 288
440 249
460 234
575 187
ZR/ZT 200 compressors designed for a maximum inlet temperature of 50 ˚C/122 ˚F with IE3 motor
or equipped with oversized IE3 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 257
440 219
460 213
575 168
ZR/ZT 250 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE2 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 288
440 249
460 234
575 187
ZR/ZT 250 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE3 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380 281
440 239
460 232
575 184
ZR/ZT 250 compressors designed for a maximum inlet temperature of 50 ˚C/122 ˚F with IE2 motor
or equipped with oversized IE2 motor
Instruction book
2920 1815 04 309

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco ZR 275 and is the answer not in the manual?

Atlas Copco ZR 275 Specifications

General IconGeneral
BrandAtlas Copco
ModelZR 275
CategoryAir Compressor
LanguageEnglish

Related product manuals