380 V - 60 Hz IEC
Compressors designed for a maximum ambient temperature of 104 °F (40 °C) with IE2 motors
Type Cables (H07V2-K) IEC 60364-5-52:
E & 4
mm
2
Fuses gL/gG
(A)
Maximum cable
length
(m)
ZR/ZT 110 2 x (3x 120 + 70) 2X (3X 250) 247
ZR/ZT 145 4 x (3x 95 + 50) 2X (3X 315) 179
ZR/ZT 160 4 x (3x 120 + 70) 2X (3X 400) 175
ZR/ZT 200 4 x (3x 120 + 70) 2X (3X 400) 175
ZR/ZT 250 4 x (3x 120 + 70) 2X (3X 400) 175
ZR/ZT 275 4 x (3x 150 + 95) 2X (3X 500) 179
Compressors designed for a maximum ambient temperature of 104 °F (40 °C) with IE3 motors
Type FLA MCA Proposed cable
(mm²)
Maximum
cable
length (m)
Proposed
fuses (A)
(gL/gG)
Maximum
fuse (A)
(gL/gG)
Icc
ZT/ZR 110 259 285 4 X (3 X 35+16) 106 2 x(3 X 200) 315 50 kA
ZT/ZR 145 339 373 2 X (3 X 120+70) 245 2 x(3 X 250) 400 50 kA
ZT/ZR 160 363 399 4 X (3 X 95+50) 177 2 x(3 X 315) 400 50 kA
ZT/ZR 200 441 485 2 X (3 X 185+95) 258 2 x(3 X 315) 500 50 kA
ZT/ZR 250 513 564 4 X (3 X 120+70) 176 2 x(3 X 400) 500 50 kA
ZT/ZR 275 655 720 4 X (3 X 150+95) 179 2 x(3 X 500) 500 50 kA
FLA and MCA based on an air-cooled full option compressor.
Icc only achieved with recommended fuses.
Compressors designed for a maximum ambient temperature of 122 °F (50 °C) with IE2 motors
Type Cables (H07V2-K) IEC 60364-5-52:
E & 4
mm
2
Fuses gL/gG
(A)
Maximum cable
length
(m)
ZR/ZT 110 2 x (3x 150 + 95) 2X (3X 250) 319
ZR/ZT 145 4 x (3x 95 + 50) 2X (3X 315) 179
ZR/ZT 160 4 x (3x 150 + 95) 2X (3X 400) 175
ZR/ZT 200 4 x (3x 150 + 95) 2X (3X 400) 175
ZR/ZT 250 4 x (3x 150 + 95) 2X (3X 400) 175
Instruction book
220 2920 1815 04