Minimum
setting
Factory
setting
Maximum
setting
Compressors designed for a maximum
inlet temperature of 122 ˚F
˚F 212 491 500
Compressor element 1 outlet temperature
(shut-down level) (10.0, 10.4 and 12.0 bar
(175 psi) compressors)
Compressors designed for a maximum
inlet temperature of 40 ˚C
˚C 226 260 260
Compressors designed for a maximum
inlet temperature of 104 ˚F
˚F 439 500 500
Compressors designed for a maximum
inlet temperature of 50 ˚C
˚C 256 260 260
Compressors designed for a maximum
inlet temperature of 122 ˚F
˚F 493 500 500
Compressor element 1 outlet temperature
(shut-down warning level) (13.0 bar (190
psi) compressors)
˚C 100 255 260
Compressor element 1 outlet temperature
(shut-down warning level) (13.0 bar (190
psi) compressors)
˚F 212 491 500
Compressor element 1 outlet temperature
(shut-down level) (13.0 bar (190 psi)
compressors)
˚C 256 260 260
Compressor element 1 outlet temperature
(shut-down level) (13.0 bar (190 psi)
compressors)
˚F 493 500 500
Compressor element 2 outlet temperature
(shut-down warning level) (7.0, 7.5 and 8.6
bar or 100, 110 and 115 psi compressors)
Compressors designed for a maximum
inlet temperature of 40 ˚C
˚C 100 210 220
Compressors designed for a maximum
inlet temperature of 104 ˚F
˚F 212 410 428
Compressors designed for a maximum
inlet temperature of 50 ˚C
˚C 100 225 235
Compressors designed for a maximum
inlet temperature of 122 ˚F
˚F 212 437 455
Compressor element 2 outlet temperature
(shut-down level) (7.0, 7.5 and 8.6 bar or
100, 110 and 115 psi compressors)
Compressors designed for a maximum
inlet temperature of 40 ˚C
˚C 211 220 220
Compressors designed for a maximum
inlet temperature of 104 ˚F
˚F 412 428 428
Compressors designed for a maximum
inlet temperature of 50 ˚C
˚C 226 235 235
Compressors designed for a maximum
inlet temperature of 122 ˚F
˚F 439 455 455
Instruction book
2920 1815 04 107