31
of the second stage. Rinsing is particularly important with the chrome plated brass first
stages (M1, B2, Z2/Z3) to maintain it in top condition and keep the chrome looking
attractive. Avoid soaking the regulator unpressurized, as water may enter the
second stage and first stage mechanism. If the second stage is purged when it
is rinsed or soaked, it is a good idea to re-connect the regulator to a tank and blow out
any water that may have entered the first or second stage.
Store the regulator away from direct sunlight to prevent fading and deterioration of the
rubber and plastic parts. Keep away from excessive heat, humidity or insects.
REQUIRED SERVICE
The major service interval for the Atomic Aquatics regulators is once every 2 years
or 300 dives*. We recommend that you take your regulator to an authorized Atomic
Aquatics dealer annually for a safety inspection. At this time, they will inspect and
check for proper operation, and advise if a major service is required. The major service
will include replacement of all seals, seats and o-rings. The labor charges for this service
will vary with the individual dealer. Parts replacement will be in accordance to the terms
of the limited lifetime warranty in this manual.
*T3: 3 years or 300 dives.
POST DIVE CARE / REQUIRED SERVICE