ATON AH66T INSTALLATION MANUAL
© ATON 2010 | All rights reserved. Page 23
Sense Input Connections
The Sense Inputs of the AH66T are used to conditionally execute zone monitor power on
and off macros. The sensor is connected to the monitor and to the Sense Input
corresponding to the zone number. The ATON configuration software automatically creates
a macro that checks the status of the monitor prior to issuing the power command. This
prevents the TV from being inadvertently turned on or off when changing sources or
turning a zone on or off.
Figure 3-6: Sense Inputs
The AH66T provides +5 VDC to the TIP (VSNS) connection to power the Sensor. When the
Sensor is activated, it shorts the ring (SNS) to the sleeve (GND) thereby triggering the
AH66T’s Sense Input.
Available ELAN sensors include: AUDIO, VIDEO, CONTACT CLOSURE, VOLTAGE,
LED/LIGHT, and CURRENT/MAGNETIC FIELD sensors.