39
After selecting a certain group of processes, click "Apply" to directly export the process
parameters of this group to the welding work interface. Click "Import" to store the
parameters of the welding interface into this group of processes. The process
parameters in the process interface can be permanently saved even in the power failure
situation. Users can input the process name to identify different process parameters.
2.7 Advanced parameter description
The password for entering advanced parameters is 2000. The explanation and
description of the advanced parameters of the handheld welding control system are listed
below. Users can set appropriate parameters according to actual needs during use.
1) Fac delay:
When the laser enable is turned on, after stopping the light, the motor stops rotating
after this period of delay. The maximum stop delay is 999s.
2) Power ramp up
Set the power ramp-up delay (the time required for the output power to rise from the
starting power to the peak power);
3)Laser power
Set the power of the laser.
4) Power ramp down
Set the power slow-down delay (the time it takes for the output power to drop from