TH147E-P & TH148ELE-P 400-147-016-C 2008-01-08 1/4
The TH147E-P and TH148ELE-P thermostats can be used to control:
a forced air system - 2 or 3 wires
a hot water system with or without pump - 2 wires
a millivolt system - 2 wires
Note: The installation must be performed by an electrician.
2.1 Removing the Old Thermostat
IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK, CUT
POWER TO THE HEATING SYSTEM.
n Remove the old thermostat to access the wires.
o Identify and label each wire (with the corresponding letter on the
wire terminal) and remove them from the terminals.
p If necessary, strip the end of each wire (maximum of 6 mm).
2.2 Installing the New Baseplate
Choose a location approximately 1.5 m above the floor and on
an inside wall. Avoid draughty areas (top of staircase, air outlet,
etc.), dead air spots (behind doors), direct sunlight or areas near
concealed pipes or chimneys.
n Remove the thermostat faceplate.
o Loosen the locking screw in order to separate the thermostat
from its baseplate (the screw cannot be completely removed).
p Gently tilt the thermostat upwards.
q Pass the wires through the opening of the baseplate and secure
the baseplate to the wall using the appropriate screws.
2.3 Terminal Designations
n
Introduction
1.
Features
TH147E-P
TH148ELE-P
Pump protection X X
Programmable cycle length X X
Battery replacement indicator X X
Backlit display X X
Programming:
- Preprogrammed schedule
- Temporary bypass
- Time display (12 h or 24 h)
X
X
X
X
X
X
X
X
Interchangeable faceplates X X
Unoccupied mode activated remotely X
Automatic daylight savings changeover X
Display
Adjustment
buttons
Backlight
button
Comfort
temperature
preset
Mode selection /
program exit
Program
button
Economy
temperature
preset
Temperature
Schedule
Time
Manual mode
Heating is On
: Comfort temperature indicator
: Economy temperature indicator
Day
Display
Appears when the
setpoint temperature
is displayed
Low battery indicator
Automatic mode
Unoccupied mode
o
Installation
2.
R Power
W Load
Un / Un Unoccupied mode input (TH148ELE-P only)
TH147E-P & TH148ELE-P
Installation and User Guide
Programmable Thermostats
400-147-016-C (TH147_148 P Europe) ENG.fm Page 1 Tuesday, January 8, 2008 2:47 PM
Question and Answer IconNeed help?

Do you have a question about the Aube Technologies TH147E-P and is the answer not in the manual?

Aube Technologies TH147E-P Specifications

General IconGeneral
BrandAube Technologies
ModelTH147E-P
CategoryThermostat
LanguageEnglish

Summary

Introduction

System Compatibility

Supports forced air, hot water, and millivolt systems with specific wiring configurations.

Interface Overview

Details the thermostat's display, adjustment buttons, and mode selection controls.

Installation

Removing Old Thermostat

Safety precautions and steps for removing the old thermostat and identifying wires.

Installing New Baseplate

Guidance on selecting an optimal location and securely mounting the new thermostat baseplate.

Terminal Designations

Defines the terminal designations for power, load, and unoccupied mode input.

System Connections

Connecting Heating System

Details connecting the heating system wires to the thermostat terminals.

Unoccupied Mode Input

Explains the unoccupied mode input for remote temperature control on TH148ELE-P.

Connecting to CT240

Instructions for connecting the thermostat to an Aube CT240 telephone controller.

Home Automation Connection

Guidance for connecting the thermostat to a 12-VDC home automation system.

Battery Installation

Installing Batteries

Steps for correctly installing the alkaline batteries into the thermostat.

Basic Functions

Backlight Functionality

Explains how the display illuminates when a button is pressed.

Displaying Temperature

How to view the actual and setpoint temperatures on the display.

Setting the Temperature

Instructions on how to adjust the desired temperature using the buttons.

Comfort and Economy Temperatures

Details the two preset temperature modes and how to set them.

Control Modes

Manual Mode Operation

How to manually set the temperature using the Mode and adjustment buttons.

Automatic Mode Operation

How to enable automatic temperature control based on the programmed schedule.

Temporary Bypass

Explains how temporary temperature changes affect automatic or unoccupied modes.

Unoccupied Mode

How to activate the unoccupied mode and its effect on temperature settings.

Low-Battery Indicator

Low-Battery Warning

Description of the low-battery icon and its implications for thermostat operation.

Programming

Setting Clock and Day

Step-by-step guide to setting the current time and day on the thermostat.

Setting Date (TH148ELE-P)

Instructions for setting the date, relevant for daylight savings on TH148ELE-P.

Schedule Overview

Details the default Comfort and Economy temperature schedules for weekdays and weekends.

Modifying the Schedule

Procedure for customizing the Comfort and Economy temperature schedule periods.

Configuration Settings

Accessing Configuration Menu

How to enter the configuration menu using the backlight button.

Configuration Parameters

Overview of adjustable parameters like time display, pump protection, and temperature settings.

Warranty Information

Product Warranty

Details the three-year warranty, exclusions, and how to claim service.

Technical Specifications

Product Specifications

Lists key technical details including power, load, temperature ranges, and dimensions.

Technical Assistance

Contact Technical Support

Provides contact information for technical support and product inquiries.

Related product manuals