Configures automatic door locking based on passive or active arming mode via DIP switch 1.
Enables/disables automatic door locking/unlocking when ignition is turned on/off via DIP switch 2.
Selects passive (automatic) or active (transmitter) arming mode via DIP switch 3.
On-board 10A relay for factory-installed trunk release solenoid.
Hardwire remote output for optional upgrades like remote starter or window roll-up.
Connects dark green/white wire to door pin switch for entry lighting and alarm flash.
Connect dark blue/white wire for illumination feature and passive arming.
Provides +12V output when disarmed or ignition is on, used for passive system control.
Route grey/black connector from valet switch to alarm control module.
Details wiring for orange, blue/white, yellow, white, green, blue wires for door lock relays.
Unlocks driver door on first press, all doors on second press within 3 seconds.
Sets door trigger circuit polarity for ground or positive switched dome light circuits.
Provides output to control an optional parking light flasher relay.
Provides output to control an optional starter cut relay, immobilizing the vehicle when armed.
Details programming channels 1, 2, and 3 for transmitter button assignments and system functions.
Provides toll-free number for technical assistance during installation.
Mount inside passenger compartment, avoid engine compartment and electronic components.
Mount in an accessible location, preferably concealed, drill 1/4" hole if needed.
Connect to a +12 VDC constant battery source.
Connect to a solid, metal part of the vehicle's chassis.
Connect to a source hot during ignition ON and START positions.
Connect to terminal 86 for optional starter cut relay.
Connect to terminal 86 for optional parking lamp flasher relay.
Low current (300mA) output for optional devices, latches to ground.
NO/COMMON contacts for trunk release or other accessories, 10A max.
Wiring instructions for ground switched door lock circuits.
Details wiring for positive switched circuits using yellow and white wires.
Instructions for connecting to 5-wire alternating door lock circuits.
Connects unlock relay outputs for 2-step unlock operation.
Wiring for green/black (ground pulse) and red/black (+12V source) 2-step unlock.
Extend antenna wire to full length, route away from damage.
Check options, explain system operation to customer.
Wrap alarm wires in tubing or tape, secure with ties to prevent damage.