Time line
The LCD display displays the time line divided into 24 sections, where each
section corresponds to 1 hour of a 24-hour long day.
A black rectangle above a given hour indicates that the day temperature is
maintained, whereas no such a rectangle indicates that the night
temperature is maintained.
An example:
The above picture shows that from 06:00 to 23:00 the regulator controls the
heating device in a manner to maintain the day temperature in the room
( ). From 23:00 to 06:00 the regulator switches over to the night
temperature ( ).
In order to let the regulator know when to use the day or the night
temperature, it is necessary to assign an appropriate program to each day
of week. In order to do this, you can use one of the three factory-defined
programs:
Program no. 0 – anti-freezing
A factory program designed for setting the anti-freezing temperature.
Selecting this program causes the maintaining of the anti-freezing
temperature throughout the day.
Program no. 1 – week days
A factory program that cannot be modified. Setting this program causes
the heating devices to maintain the day temperature from 05:00 to 0800
and from 15:00 to 23:00.
Program no. 2 – weekend
A factory program that cannot be modified. Setting this program causes
the heating device to maintain the day temperature from 06:00 to 23:00.
Program no. 3, 4,….,9 – user defined
Programs no. 3 through 9 are user-defined programs. The user can
modify and adapt them at will.
Factory programs
INTRODUCTION TO PROGRAMMING
3. Using the and buttons, set the desired temperature setpoint.
4. By pressing the button, toggle between the available kinds
of temperature to be set ( , , );
5. After setting all 3 temperature setpoints, confirm the setting with
the button .
NOTE: The value of the night temperature setpoint can be equal to or lower
than the value of the day temperature setpoint. It is not possible to
set the night temperature setpoint higher than the day temperature
setpoint.
,,,‚ ,,,,,,
TEMP
1. Press the button.
2. The current temperature setpoint will
appear on the display with the symbol:
– day temperature,
– night temperature,
– anti-freeze temperature.
TEMP
Programming the day ( ), night ( )
and anti-freeze ( ) temperatures
The AURATON 2025 / AURATON 2025 RTH regulator allows for programming
3 kinds of temperatures:
Day temperature ( ) - from 5 to 30 °C
Night temperature ( ) - from 5 to 30 °C
Antifreeze temperature ( ) - from 4 to 10 °C
In order to set one of the above temperatures:
Monday – Friday:
The heating device maintains day temperature from 05:00 to 08:00
and from 15:00 to 23:00.
Saturday – Sunday
The heating device maintains day temperature from 06:00 to 23:00.
Default temperature setpoints:
Day temperature – 21,0 C
Night temperature – 19,0 C
Anti-freeze temperature – 7,0 C
°
°
°
Default settings of programs