EasyManua.ls Logo

Austa AU Series - 7 Specification

Austa AU Series
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
7.Specification
7.1 Specification
Technical Data
AU50K3P
AU60K3P
AU70K3P-HV
AU75K3P-HV
DC Input Data
Max. DC input power (KW)
75
90
105
112.5
Max. DC input voltage(VDC)
1100
MPPT voltage range(VDC)
250~1000
Max. DC current(A)
45/45/45
Recommended working
voltage(VDC)
650
740
MPPT number
3
Max. input strings per MPP tracker
4/4/4
AC Output Data
Rated output power (KW)
50
60
70
75
Max. AC power (KVA)
55
66
77
82.5
Max. output current(A)
80
96
89
95
Rated power grid voltage(Vac)
400
500
Power grid voltage range(Vac)
310~480
422-550
Rated power grid frequency
50Hz/60Hz
Grid frequency range
45~55Hz/55~65Hz
THD
<2%(Under the rated power)
Power factor
>0.99(Under rated power)/Adjustable range 0.8(Leading)~0.8
(Lagging)
DC component
<0.5%(Under rated power)
System Data
Max. Efficiency(%)
98.7%
98.9%
99%
99%
Euro. efficiency(%)
98.3%
98.5%
98.5%
98.5%
Humidity
0~100%,No condensation
Cooling
Fan
Allowed ambient temperature
range
-25℃~+60℃
Contents
7