Digital Counter / Timer / Tach User Manual, 1st Ed.
1-800-633-0405
2-124
Dip Switch Settings - Table 1
Switch Function Off On
1 Dip switch Disabled Enabled
2 Counting mode Counting up Counting down
3
Output mode See Output Mode Table - Table 2
4
5 Counting speed 30cps 10Kps
6 Reserved - -
7 Input signal NPN PNP
8
Reset signal
pulse width
20 ms 1 ms
DIP Switch Set Up of the CTT Parameters:
Output Mode - Table 2
Switch 3 Switch 4 Output Mode
OFF OFF
F
ON OFF
N
OFF ON
C
ON ON
R
Outputs
Load
Load
OUT1
NPN/
SINKING
OUT2
SPDT
Load
OUT1
SPST
0V CP1
CP2/
GATE (Pause)
+12V RST1
RST2/
START
CP2
Input
CP1
Input
Reset
0V CP1
+12V RST1
RST2/
START
Reset
0V CP1
+12V RST1
RST2/
START
Reset
PNP
INPUTS
L-
Load
OUT2
NPN/
SINKING
Load
0V CP1
+12V RST1
RST2/
START
Reset
L-
L+
NPN
INPUTS
CP1
Input
CP2
Input
CP2
Input
CP1
Input
CP1
Input
CP2
Input
L+
+VDC 0VDC
Externally Powered
Internally Powered
+VDC 0VDC
Externally Powered
Internally Powered
(Optional)
(Optional)
(Optional)
(Optional)
+VDC
0VDC
+VDC
0VDC
10
9
321
15
14
10
15
876
1312
11
876
131211
876
131211
321
876
131211