GS1 Series AC Drive User Manual
3–7
Chapter 3: Keypad Operation and Quickstart
Acceleration Time Setting: 5.0
Range: 0.1 to 600 sec Default Setting: 10 sec
The motor should accelerate from 0 RPM to Base RPM (0-03) in 5
seconds.
Deceleration Time Setting: 5.0
Range: 0.1 to 600 sec Default Setting: 30 sec
The motor should decelerate from Maximum RPM (0-04) to 0 RPM in
5 seconds.
Volts/Hertz Settings Setting: 1
Range: 0 - General Purpose Default Setting: 0
1 - High Starting Torque
2 - Fans and Pumps
3 - Custom
The GS1 Series AC drive has some predefined torque settings that meet
the needs of most applications. A custom setting is available if needed.
In this example, the application requires a high starting torque.
Source of Operation Command Setting: 2
Default Setting: 0
Settings 0 Operation Determined by Digital Keypad
1 Operation determined by external control
terminals. Keypad STOP is enabled.
2 Operation determined by external control
terminals. Keypad STOP is disabled.
3 Operation determined by RS485 interface.
Keypad STOP is enabled.
4 Operation determined by RS485 interface.
Keypad STOP is disabled.
The AC drive operation will be determined by external control
terminals and the keypad stop will be disabled.
3-00
2-00
1-02
1-01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Automationdirect.com GS1-10P2 and is the answer not in the manual?

Automationdirect.com GS1-10P2 Specifications

General IconGeneral
BrandAutomationdirect.com
ModelGS1-10P2
CategoryController
LanguageEnglish

Related product manuals