Summary

Safety Considerations

Safety Precautions

Crucial safety warnings and operational guidelines to prevent injury, death, or equipment damage.

Cautions during Use

Usage Precautions

Essential guidelines for safe and proper product operation, including environmental and electrical considerations.

Connections

System Operation and Maintenance

Installation and Inspection Procedures

Checks for installation conditions, wiring, daily, and regular maintenance.

Overview

This document describes the Autonics SFC / SFC-R Series Safety Controllers and Safety Relay Units, designed to enhance safety in industrial environments. These devices are crucial for applications requiring high safety integrity levels, such as those involving machinery that could cause serious injury or economic loss.

Function Description

The SFC / SFC-R Series units serve as central components in safety control systems, monitoring various safety inputs and providing safety outputs to control hazardous machinery. They are designed to achieve high safety performance levels, conforming to international safety regulations and standards such as SIL3, SIL CL3, PLe, CE, UL Listed, and S Mark.

The core function of these units is to process signals from safety input devices like emergency stop buttons, safety light curtains, safety door lock switches, and non-contact door switches. Based on these inputs and configured logic, the controllers activate or deactivate safety outputs, which typically control contactors or motor controllers to bring machinery to a safe state.

Different models within the series offer various output types, including P-channel FET safety outputs for instantaneous or off-delay control, and relay contact safety outputs, also with instantaneous or off-delay capabilities. The off-delay feature allows for controlled shutdown sequences, crucial for applications where immediate power cut-off could be hazardous or damaging.

Auxiliary outputs (X1, X2) are also provided. Auxiliary output 1 (X1) mirrors the state of the instantaneous safety outputs, turning ON when they are ON and OFF when they are OFF. Auxiliary output 2 (X2) indicates an error condition, turning ON when the ERR indicator is active. It is critical to note that these auxiliary outputs are non-safety outputs and must not be used for safety-related purposes.

The units support various connection configurations, including logic (AND) connections for integrating multiple safety functions and expansion relay unit connections to increase the number of available safety outputs. This modularity allows for flexible system design to meet diverse application requirements.

Usage Features

The SFC / SFC-R Series units are designed with user-friendly features to facilitate installation, operation, and troubleshooting.

  • Compact Design: The slim size (17.5 / 22.5 / 35 mm) of these units helps save installation space in control panels, which is particularly beneficial in crowded industrial environments.
  • Visual Status Indicators: Multiple LED indicators are integrated to display the status of various functions, including power, safety inputs, logic inputs, error conditions, feedback, and outputs. These visual cues allow operators to quickly assess the operational state of the device and identify potential issues.
  • Connection Options: Both screw and screwless connection models are available, offering flexibility based on installation preferences and maintenance requirements. Screwless terminals can expedite wiring and reduce the risk of loose connections due to vibration.
  • Configurable Off-Delay: The units offer configurable off-delay output times, which can be set for advanced applications, non-contact door switches, or relay output models. This feature is essential for applications requiring a controlled stop rather than an abrupt shutdown, allowing for safe deceleration or process completion.
  • Logic and Expansion Capabilities: The ability to perform logic (AND) connections allows for the integration of multiple safety inputs into a single safety function. Furthermore, the option to connect expansion relay units significantly extends the number of available safety outputs, making the system scalable for complex machinery.
  • Compliance with Standards: The product structure is designed to conform to international safety regulations and standards, ensuring reliability and acceptance in various global markets. This compliance simplifies the process of achieving machine safety certifications.
  • Installation Flexibility: The units can be installed on a device panel or DIN rail inside a control room with an IP54 or higher protection structure. For DIN rail mounting, an End plate (sold separately) is recommended for secure fixation. In environments with high vibration or shock, screw mounting to the panel is advised to prevent dislodgement.
  • Responsible Operation: The manual emphasizes the importance of a "responsible person" who is fully knowledgeable about the product's installation, settings, use, and maintenance, and familiar with relevant laws and standards. This person is also responsible for educating machine users on proper operation and reporting errors.

Maintenance Features

Effective maintenance is crucial for ensuring the continuous safe operation of safety devices. The SFC / SFC-R Series includes features and recommendations to support this.

  • Error Indication System: When an error occurs, the ERR indicator, along with other relevant indicators, will turn ON or flash to signal the cause of the error. The manual provides a detailed table linking specific indicator states to potential causes and recommended check and measure actions. This system aids in rapid diagnosis and resolution of issues, minimizing downtime and maintaining safety integrity.
  • Regular Inspections: The manual mandates daily and regular inspections (every six months) to ensure the product's continued proper function and to prevent malfunctions that could lead to personal injury or economic loss. These inspections cover several key areas:
    • Installation Conditions: Verifying that the product and connected safety sensors are installed at the calculated safety distance from hazardous zones, and that the installation environment does not cause material deformation. It also checks for secure fixation on DIN rails or panels and absence of product damage.
    • Wiring Connection: Confirming that the power supply for safety-related functions is 24VDC and meets specifications, polarity is correct, wiring is undamaged, and connections are appropriate for the intended purpose. It also ensures that auxiliary outputs are not connected to safety-related parts of the control system.
    • Safety System-Check in Operation: This involves inspecting the system without an operator in the hazardous zone, verifying that the safety system stops immediately when the safety input signal is OFF, and that it maintains its status during power shutdowns. It also checks that the actual machine response time is less than the calculated time.
  • Troubleshooting Guidance: The comprehensive error indication table and troubleshooting steps provided in the manual empower maintenance personnel to address common issues effectively. This self-help capability reduces reliance on external support and speeds up problem resolution.
  • Product Longevity: By adhering to the recommended installation and maintenance practices, users can maximize the lifespan and reliability of the safety controllers, ensuring long-term safety performance.
  • Manufacturer Support: In cases where the recommended measures are not effective, users are advised to contact Autonics, indicating that manufacturer support is available for complex issues or internal circuit failures.

Autonics SFC-N322-23 Specifications

General IconGeneral
ModelSFC-N322-23
CategoryController
Output TypeRelay
Number of Inputs2
Count Speed1 kHz
DisplayLED
Operating Temperature-10 to 55°C
Storage Temperature-20 to 70°C