1: The weight includes packaging. The weight in parentheses is for unit only.
Environment resistance is rated at no freezing or condensation.
Theunitcannotbeconguredwithanyrandomcombinationfromtheaboveorderinginformation.Please
refer to Specicationsforpossiblecongurations.
1: TZN4S only supports Event 1 option output.
Dual PID Control Temperature Controller
TZN SERIES
I N S T R U C T I O N M A N U A L
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.
Safety Considerations
Pleaseobserveallsafetyconsiderationsforsafeandproperproductoperationtoavoidhazards.
Safety considerations are categorized as follows.
Warning
Failure to follow these instructions may result in serious injury or death.
Caution
Failure to follow these instructions may result in personal injury or product damage.
The symbols used on the product and instruction manual represent the following
symbol represents caution due to special circumstances in which hazards may occur.
Warning
Ordering Information
TZN 4 S 1 4 R
Item
Digit
Size
Option output
Powersupply
Control
output
R
Relay output
S
SSR drive output
C
Current output
4
100-240VAC 50/60Hz
1
1
Event 1
2
Event 1 + Event 2
R
Event1+PVtransmission(DC4-20mA)
T
Event 1 + RS485 communication
A
Event1+Event2+PVtransmission(DC4-20mA)
B
Event 1 + Event 2 + RS485 communication
S
DIN W48×H48mm
M
DIN W72×H72mm
W
DIN W96×H48mm
H
DIN W48×H96mm
L
DIN W96×H96mm
4
9999(4-digit)
TZN
Temperaturecontroller(PIDNewType)
Specications
Series
TZN4S TZN4M TZN4W TZN4H TZN4L
Powersupply 100-240VAC 50/60Hz
Allowable voltage range 90 to 110% of rated power voltage
Powerconsumption
Max.5VA(100-
240VAC50/60Hz)
Max.6VA(100-240VAC50/60Hz)
Display method 7-segmentLED(PV:red,SV:green)
Character
size
PV(W×H) 7.8×11.0 mm 8.0×13.0 mm
8.0×10.0 mm
7.8×11.0 mm 9.8×14.2 mm
SV(W×H) 5.8×8.0 mm 5.0×9.0 mm 5.8×8.0 mm 8.0×10.0 mm
Input
type
RTD DPt100Ω,JPt100Ω,3-wire(allowedresistance:max.5Ωperline)
TC
K(CA),J(IC),R(PR),E(CR),T(CC),S(PR),N(NN),W(TT)
(allowedresistance:max.100Ωperline)
Analog 1-5VDC ,0-10VDC ,DC4-20mA
Display accuracy F.S. ±0.3% or 3
,greatervalue
Control
output
Relay 250VAC 3A 1c
SSR Max. 12VDC ±3V 30mA
Current DC4-20mA(loadresistancemax.600Ω)
Option
output
EVENT1 250VAC 1A 1a
EVENT2
-
250VAC 1A 1a
PVtransmission
-
DC4-20mA(loadresistancemax.600Ω)
Communication
-
RS485 communication
Control method ON/OFF,P,PI,PD,PIDF,PIDScontrol
Alarm output hysteresis 1 to 100
(0.1to100.0
)variable
Proportionalband(P) 0.0 to 100.0%
Integraltime(I) 0to3,600sec
Derivativetime(D) 0to3,600sec
Controlperiod(T) 1 to 120 sec
Sampling period 0.5 sec
LBA setting 1 to 999 sec
Ramp setting RampUp,RampDown:1to99mineach
Dielectric strength 2,000VAC50/60Hzfor1min(betweeninputandpowerterminals)
Vibration
Mechanical
0.75mmamplitudeatfrequency10to55Hz(for1min)ineachX,Y,Zdirectionfor2hours
Electrical
0.5mmamplitudeatfrequency10to55Hz(for1min)ineachX,Y,Zdirectionfor10min
Relay
life cycle
Control output
Mechanical:min.10,000,000operations,
Electrical:min.100,000operations(250VAC3Aresistanceload)
Option output
Mechanical:min.20,000,000operations,
Electrical:min.500,000operations(250VAC1Aresistanceload)
Insulation resistance Over 100MΩ(at500VDCmegger)
Noise immunity Squareshapednoisebynoisesimulator(pulsewidth1
)±2kVR-phase,S-phase
Memory retention Approx.10years(non-volatilesemiconductormemorytype)
Environ
ment
Ambient temp. -10 to 50
,storage:-20to60
Ambient humi. 35to85%RH,storage:35to85%RH
Approval
Weight
1
Approx. 226g
(approx.164g)
Approx. 355g
(approx.246g)
Approx. 351g
(approx.232g)
Approx. 474g
(approx.303g)
Input Type and Range
Conguring Input Type
Pleaseconguretheinternalswitchesbeforesupplyingpower.Aftersupplyingpower,configuretheinputtype
[
IN-T
] in parameter group 2 according to the input type.
●Detachingthecase
Pressthefrontcasethenpullthecasetodetachthecasefromthebody.
Conguretheinternalswitchesasinputtype.
Input type S/W 1 S/W 2
Thermocouple
1 1 mA V
RTD
Analog
Voltage
(0-10VDC,
1-5VDC)
2 2
mA V
Current
(DC4-20mA)
2 2
mA V
Dimensions
Connections
(unit:mm)
(unit:mm)
Size
Series
A B C D
TZN4S Min. 55 Min. 62 45.5
+0.5
0
45.5
+0.5
0
TZN4M Min. 91 Min. 91 68
+0.7
0
68
+0.7
0
TZN4W Min. 112 Min. 50 92
+0.8
0
45.5
+0.6
0
TZN4H Min. 50 Min. 102 45
+0.6
0
92
+0.8
0
TZN4L Min. 98 Min. 106 91
+0.5
0
91
+0.5
0
●TZN4S
30
73
12
10
4
3.5
10
48
10 79.5
10.5
100
45
●TZN4M
10
72
73
83
67
●TZN4W
96
13
90
10
45
48
●TZN4H
48
13 90
10
90
96
AT
SV2 EV2
EV1
OUT
TEMPERATURE CONTROLLER
ATMD
PV
SV
°C
●TZN4L
96
13
90
10
90
A
C
D
B
45.4
61
3.9
7.4
15
4.5
4.2
41
12.2
48
47.8
61
TZN4S Series TZN4M,TZN4W,TZN4H,TZN4LSeries
Bracket Panel cut-out dimensions
●TZN4S
●TZN4M
●TZN4L
EV1 OUT
250VAC 1A 1a
EV2 OUT
250VAC 1A 1a
SV2 IN
Max.5VDC
250
B'
TC
RTD
SENSOR
B
A
-
+
MAIN OUT
SSR Current
12VDC ±3V
30mA Max.
DC4-20mA
Load600ΩMax.
mA
V
- -
+ +
15
14
15
14
MAIN OUT
250VAC 3A 1c
Resistive load
PVOUT
DC4-20mA
H
C
L
-
+
RS485(A+)
RS485(B-)
-
+
SOURCE
100-240VAC
50/60Hz 6VA
●TZN4H
SOURCE
100-240VAC
50/60Hz 6VA
EV1 OUT
250VAC 1A 1a
EV2 OUT
250VAC 1A 1a
SV2 IN
Max.5VDC
250
MAIN OUT
250VAC 3A 1c
Resistive load
PVOUT
DC4-20mA
B'
TC
RTD
SENSOR
B
A
H
C
L
-
+
RS485(A+)
RS485(B-)
-
+
-
+
●TZN4W
EV1 OUT
250VAC
1A 1a
EV2 OUT
250VAC
1A 1a
SV2 IN
Max.5VDC
250
B'
RTD
TC
SENSOR
B A
- +
SOURCE
100-240VAC
50/60Hz 6VA
MAIN OUT
250VAC 3A 1c
Resistive load
PVOUT
DC4-20mA
H
C
L
-
-
+
+
RS485
(A+)
RS485
(B-)
MAIN OUT
SSR Current
-
+
V
3
2
12VDC ±3V
30mA Max.
-
+
3
2
mA
DC4-20mA
Load600ΩMax.
MAIN OUT
SSR Current
-
+
V
7
6
12VDC ±3V
30mA Max.
-
+
7
6
mA
DC4-20mA
Load600ΩMax.
MAIN OUT
SSR Current
-
+
V
15
14
12VDC ±3V
30mA Max.
-
+
15
14
mA
DC4-20mA
Load600ΩMax.
MAIN OUT
SSR Current
-
+
V
15
14
12VDC ±3V
30mA Max.
-
+
15
14
mA
DC4-20mA
Load600ΩMax.
SOURCE
100-240VAC
50/60Hz 5VA
EV1 OUT
250VAC
1A 1a
SV2 IN
Max.5VDC
250
MAIN OUT
250VAC 3A 1c
Resistive load
B'
RTD
TC
SENSOR
B
A
H
C
L
+
-
-
+
EV1 OUT
250VAC 1A 1a
EV2 OUT
250VAC 1A 1a
SV2 IN
Max.5VDC
250
MAIN OUT
250VAC 3A 1c
Resistive load
PVOUT
DC4-20mA
SOURCE
100-240VAC 50/60Hz 6VA
H
RS485(A+)
RS485(B-)
C
L
-
-
-
+
+
+
B'
RTD
TC
SENSOR
B
A
-
+
DRW170714AA
Caution
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury
or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles,
railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failuretofollowthisinstructionmayresultinre,personalinjury,oreconomicloss.
2. Install on a device panel to use.
Failure to follow this instruction may result in electric shock.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failuretofollowthisinstructionmayresultinelectricshockorre.
4. Check 'Connections' before wiring.
Failuretofollowthisinstructionmayresultinre.
5. Do not disassemble or modify the unit.
Failuretofollowthisinstructionmayresultinelectricshockorre.
1. When connecting the power input and relay output, use AWG 20(0.50mm
2
) cable or over and tighten
the terminal screw with a tightening torque of 1.0N
.
m.
When connecting the sensor input and communication cable without dedicated cable, use AWG
28~16 cable and tighten the terminal screw with a tightening torque of 1.0N
.
m.
Failuretofollowthisinstructionmayresultinreormalfunctionduetocontactfailure.
2. Use the unit within the rated specications.
Failuretofollowthisinstructionmayresultinreorproductdamage.
3. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failuretofollowthisinstructionmayresultinelectricshockorre.
4. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity, direct sunlight,
radiant heat, vibration, impact, or salinity may be present.
Failuretofollowthisinstructionmayresultinreorexplosion.
5. Keep metal chip, dust, and wire residue from owing into the unit.
Failuretofollowthisinstructionmayresultinreorproductdamage.
The above specications are subject to change and some model may be discontinued
without notice.
※
Be sure to follow cautions written in the instruction manual and the technical descriptions
(catalog, homepage).
Input type Decimal point Display Inputrange(
) Inputrange(
)
Thermo
couple
K(CA) 1
KCaH
-100 to 1300 -148 to 2372
K(CA) 0.1
KCaL
-100.0 to 999.9 Not supported
J(IC) 1
JIcH
0 to 800 32 to 1472
J(IC) 0.1
JIcL
0.0 to 800.0 Not supported
R(PR) 1
R PR
0 to 1700 32 to 3092
E(CR) 1
ECrH
0 to 800 32 to 1472
E(CR) 0.1
ECrL
0.0 to 800.0 Not supported
T(CC) 1
TCcH
-200 to 400 -328 to 752
T(CC) 0.1
TCcL
-199.9 to 400.0 Not supported
S(PR) 1
S PR
0 to 1700 32 to 3092
N(NN) 1
NN
0 to 1300 32 to 2372
W(TT) 1
U TT
0 to 2300 32 to 4172
RTD
JPt100Ω 1
JPtH
0 to 500 32 to 932
JPt100Ω 0.1
JPtL
-199.9 to 199.9 -199.9 to 391.8
DPt100Ω 1
DPtH
0 to 500 32 to 932
DPt100Ω 0.1
DPtL
-199.9 to 199.9 -199.9 to 391.8
Analog
Voltage
0 - 10VDC
A--1
-1999 to 9999
(displayrangewillvarydependingonthe
decimalpoint.)
1 - 5VDC
A--2
Current DC4 - 20mA
A--3
a
b
<Round>
a
b
<Forked>
a Min. 3.5mm Min. 3.5mm
b Max. 7.2mm Max. 7.2mm
Useteminalsofsizespeciedbelow.
Question and Answer IconNeed help?

Do you have a question about the Autonics TZN4S and is the answer not in the manual?

Autonics TZN4S Specifications

General IconGeneral
Size48 x 48 mm
Control TypePID control
Input TypeThermocouple, RTD
Control OutputRelay, Current
Power Supply100-240VAC 50/60Hz
Display7-segment LED display
Output TypeRelay, Current, Voltage
Sampling Cycle500 ms
Operating Ambient Temperature-10 to 50°C
Storage Temperature-20 to 60 ℃
CommunicationRS-485 (Modbus RTU)
Alarm Output2 points (Relay SPDT)

Summary

Specifications and Dimensions

Dimensions Overview

Shows physical dimensions and panel cut-out sizes for installation.

Electrical and Performance Specs

Details electrical, input, output, and environmental specifications.

Safety and Precautions

General Safety Instructions

General safety warnings and precautions for proper operation.

Health and Environmental Notes

Precautions regarding health and environmental impact during use.

Wiring and Input Configuration

Output and Power Wiring

Describes wiring for power supply and output terminals.

Input and Option Wiring

Details wiring for input signals and optional modules.

Configuring Input Type

Step-by-step guide to setting the correct input signal type.

Parameter Groups and Settings

Parameter Groups 1 & 2 Setup

Configuration settings for parameter groups one and two.

Display and Alarm Settings

Configuration options for the display and alarm functions.

Functions and Communication

Digital Input and Ramp Functions

Configuration of digital input signals and the ramp function.

Dual Control Mode

Explanation and setup of the dual control operational mode.

RS485 Communication Setup

Comprehensive guide to setting up and using RS485 communication.

Device Management Software

Information on the PC software for device management.

Troubleshooting and Errors

Common Troubleshooting

Guidance on diagnosing and resolving common operational issues.

Error Display Codes

Explanation of error codes displayed on the unit.