J-140
TZN/TZ Series
TZ4SP/TZN4S
TZN4
TZ4
TZ4/TZN4
Item
Digit
Size
Option output
Power supply
Control output
4 M 1 4 RTZ
R Relay output
S SSR drive output
C Current output(DC4-20mA)
4 100-240VAC 50/60Hz
1 Event 1 output
1 Event 1 output
2 Event 1 + Event 2 output
R Event 1 + PV transmission output(DC4-20mA)
1 Event 1 output
2 Event 1 + Event 2 output
R Event 1 + PV transmission output(DC4-20mA)
A Event 1 + Event 2 + PV transmission output(DC4-20mA)
T Event 1 + RS485 communication output
B Event 1 + Event 2 + RS485 communication output
S DIN W48×H48mm (terminal block type)
SP DIN W48×H48mm (plug type)
1
ST DIN W48×H48mm (terminal block type)
M DIN W72×H72mm
W DIN W96×H48mm
H DIN W48×H96mm
L DIN W96×H96mm
4 9999 (4-digit)
TZ Temperature Controller
TZN Temperature Controller
TZ4ST
Others
Dual PID Control Temperature Controller
Features
● Dual PID auto tuning function:
High-speed response of PID control to reach to the
desired value fast, low-speed of response of PID control
to minimize the overshoot even though response is a
little bit slow.
● High display accuracy: ±0.3% (by F.S. value of each input)
● 2-step auto tuning control function
Multi-input function
(13 kinds of multi-input selection function):
Temperature sensor, voltage and current selection function.
● Various sub output function:
Includes in LBA, SBA, 7 kinds of alarm output and 4
kinds of alarm option function, PV transmission output
(DC4-20mA), RS485 communication output
● Display the decimal point for analog input
Ordering Information
The unit cannot be congured with any random combination from the above ordering information.
Please refer to '
Specications' for possible congurations.
1: 11-pin sockets (PG-11, PS-11(N)) are sold separately.
TZN/TZ Series
Comprehensive Device Management Program
(DAQMaster)
DAQMaster is comprehensive device management program for convenient management of parameters and multiple
device data monitoring.
Visit our website (www.autonics.com) to download user manual and comprehensive device management program.
< DAQMaster screen >< Computer specication for using software >
Item Minimum requirements
System IBM PC compatible computer with Intel Pentium
or above
Operating system Microsoft Windows 98/NT/XP/Vista/7/8/10
Memory 256MB or more
Hard disk More than 1GB of free hard disk space
VGA 1024×768 or higher resolution display
Others RS-232 serial port (9-pin), USB port
Please read “Safety Considerations”
in the instruction manual before using.
Question and Answer IconNeed help?

Do you have a question about the Autonics TZ4ST-24S and is the answer not in the manual?

Autonics TZ4ST-24S Specifications

General IconGeneral
ModelTZ4ST-24S
Storage Ambient Temperature-20 to 60°C
Housing MaterialPlastic
Number of Inputs1
Number of Outputs2
InputThermocouple, RTD, DC Current, DC Voltage
OutputRelay
Power Supply24V DC
Display MethodLED
Sampling Period0.5 sec
Operating Ambient Temperature-10 to 50°C
Size48 x 48 mm
Output RatingRelay output: 250 VAC~ 3 A 1a SSR drive output: 12 VDC ±1 VDC (NPN open collector), load current: max. 20 mA
Input Voltage24V DC
Response Time1 second
Control MethodON/OFF control

Summary

TZN/TZ Series Dual PID Control Temperature Controller

Product Features

Details key functionalities like Dual PID auto-tuning, high display accuracy, and multi-input capabilities.

Product Specifications

Supported Input Types

Lists supported input types including RTD, Thermocouple, and Analog signals with specifications.

Control and Alarm Parameters

Outlines control methods, PID parameters, alarm settings, and ramp function parameters.

Wiring Connections

Final Dimensions and Panel Cut-outs

Panel Cut-out Dimensions

Specifies the required panel cut-out sizes for different series models.

Accessories and Input Specifications

Input Type and Range Details

Provides detailed temperature ranges for Thermocouple, RTD, and Analog inputs in °C and °F.

Configuration and Operation Basics

Configuring Input Type

Explains how to configure internal switches for input type selection before powering on.

Parameter Group 1 Settings

PID Control Parameters

Covers PID control parameters like proportional band, integral time, derivative time, and control period.

Input Correction and Ramp Functions

Explains input correction, manual reset for offset, ramp up/down times, and lock function settings.

Parameter Group 2 Settings

Alarm Configuration

Sets up event alarms (Event 1, Event 2) and alarm option modes (e.g., Standard, Latch).

Tuning and Control Modes

Selects auto-tuning modes, PID control methods (P, PI, PD, PIDF), and heating/cooling modes.

Advanced Settings

Covers unit settings, limits, decimal points, transmission outputs, ramp function, communication, and lock settings.

Controller Functions and Tuning

Auto-Tuning Process

Describes how to perform auto-tuning for PID parameter optimization and the available modes.

Alarm Configuration and Operations

Alarm Operation Modes

Explains various alarm operation modes like deviation, absolute value, and sensor break alarms.

Advanced Control and Communication

Dual PID Control Modes

Compares high-speed and low-speed PID response modes for optimal control.

RS485 Communication Specifications

Details RS485 communication interface, protocol, connection, and speed specifications.

Communication Commands and Responses

Communication Command Format

Defines the structure and components of communication commands and responses.

Reading Measurement/Setting Values

Details the command format for reading process values and setting parameters.

Writing Setting Values

Explains the command structure for writing setting values to the controller.

Troubleshooting and Safety Precautions

Cautions for Safe Use

Lists important safety precautions and usage guidelines to prevent accidents and ensure proper operation.

Related product manuals