Highlights key functionalities like high-speed sampling, selectable relay/SSR outputs, and enhanced visibility.
Provides a detailed breakdown of model selection codes for TC series PID controllers.
Details technical parameters including power supply, input types, accuracy, and display methods.
Specifies the required panel opening dimensions for TC series controllers.
Details the dimensions and mounting methods for TC series brackets.
Information on optional terminal covers for TC series controllers.
Step-by-step guide on how to set the desired temperature value (SV) on the controller.
Details how to restore all parameters to their factory default settings.
Details parameters for alarm settings, auto-tuning, and basic PID control tuning.
Covers input types, units, correction, digital filter, and advanced control settings.
Configures the acceptable range for the set temperature value (SV).
Defines how the controller operates the output for heating, cooling, or SSR drive.
Sets up alarm conditions, hysteresis, and loop break alarm monitoring parameters.
Covers digital input functions, error handling, and parameter protection settings.
Lists the default factory settings for various parameters in Parameter Group 1 and 2.
Explains different alarm types (deviation, absolute) and their operational modes.
Defines how alarms latch, reset, or use standby sequences for notification.
Describes the function to detect sensor disconnection and trigger an alarm output.
Explains the LBA function for detecting control loop instability and triggering alarms.
Details the SSRP function for advanced control modes like cycle and phase control.
Explains Standard ON/OFF, Cycle, and Phase control modes for load operation.
Covers auto-tuning, input correction for sensor errors, and digital filtering for signal stability.
Details selection of control method, hysteresis for ON/OFF, and temperature unit display.
Details how to adjust for temperature differences (offset) in P/PD control modes.
Covers control output behavior during sensor line breaks and digital input key operations.
Describes how to prevent unauthorized changes to parameters and SV settings.
Lists common error codes, their meanings, and troubleshooting steps.
Shows typical wiring diagrams for relay and SSR drive output configurations.
Guides on basic troubleshooting and identifying operational errors for TC series controllers.
Provides important safety warnings and environmental considerations for installation and operation.