Do you have a question about the Autonics TC3YT Series and is the answer not in the manual?
Important safety instructions and potential hazards associated with unit operation and installation.
Precautions to prevent injury or product damage due to improper handling or environmental factors.
Guidance on safe operational practices, wiring, and environmental considerations for optimal performance.
Indicates the 3-digit 7-segment LED display used for showing information.
Specifies the available control modes: ON/OFF and Proportional control.
Details the supported input types, including Thermocouple K (CA) and J (IC).
Identifies the control output type as Relay (3 A).
States the required power supply voltage range: 100-240 VAC~50/60 Hz.
Specifies the front panel protection rating as IP65.
Details the available input types and their corresponding temperature ranges in Celsius and Fahrenheit.
Lists common error displays and provides troubleshooting steps for each.
Describes the initial display and operation state after power is supplied.
Explains how to set the Set Value (SV) using navigation and save keys.
Details parameters for proportional band, control cycle, offset correction, hysteresis, and input correction.
Covers input specification, SV limits, control output mode, error output, temperature unit, and lock settings.
Important safety instructions and potential hazards associated with unit operation and installation.
Precautions to prevent injury or product damage due to improper handling or environmental factors.
Guidance on safe operational practices, wiring, and environmental considerations for optimal performance.
Indicates the 3-digit 7-segment LED display used for showing information.
Specifies the available control modes: ON/OFF and Proportional control.
Details the supported input types, including Thermocouple K (CA) and J (IC).
Identifies the control output type as Relay (3 A).
States the required power supply voltage range: 100-240 VAC~50/60 Hz.
Specifies the front panel protection rating as IP65.
Details the available input types and their corresponding temperature ranges in Celsius and Fahrenheit.
Lists common error displays and provides troubleshooting steps for each.
Describes the initial display and operation state after power is supplied.
Explains how to set the Set Value (SV) using navigation and save keys.
Details parameters for proportional band, control cycle, offset correction, hysteresis, and input correction.
Covers input specification, SV limits, control output mode, error output, temperature unit, and lock settings.
| Control Method | PID control |
|---|---|
| Input Type | Thermocouple: K, J, T, S, R, B, E, N RTD: DPt100Ω, JPt100Ω |
| Output Type | Relay, Current, Voltage |
| Power Supply | 100-240VAC, 50/60Hz or 24VDC |
| Sampling Period | 0.5 seconds |
| Operating Ambient Temperature | 0-50°C (32-122°F) |
| Accuracy | ±0.3% of full scale ±1 digit |
| Ambient Temperature | 0-50°C (32-122°F) |
| Ambient Humidity | 35 to 85% RH (with no condensation) |
Loading...